Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measurement of width and distance of the posterior border of the deep lateral orbital wall using computed tomography

Authors
Lee, HwaLee, YounghenHa, SukgyuPark, MinsooBaek, Sehyun
Issue Date
12월-2011
Publisher
CHURCHILL LIVINGSTONE
Keywords
Deep lateral wall; Graves' ophthalmopathy; Orbital decompression; Orbital door jamb
Citation
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, v.39, no.8, pp.606 - 609
Indexed
SCIE
SCOPUS
Journal Title
JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY
Volume
39
Number
8
Start Page
606
End Page
609
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/111090
DOI
10.1016/j.jcms.2011.07.022
ISSN
1010-5182
Abstract
Introduction: Techniques of orbital decompression for Graves' ophthalmopathy continue to evolve. Recently the deep lateral orbital wall has been proposed as the most effective and safe site for a decompression procedure associated with the least complications. Anatomic variations with structures like the middle cranial fossa render decompression of the lateral wall more logical. We aimed to understand the anatomic localization and appearance of the lateral orbital wall by measuring the width and distance of the lateral wall on computed tomography (CT). Material and methods: The medical records of all patients who underwent orbital CT scans for ocular trauma or for confirmation of orbital disease at the Korea University hospital between January 2005 and May 2008 were reviewed retrospectively. All patients had been scanned with the same CT scanner (Philips Brilliance 64 channel CT; Philips Healthcare Systems). Patients who had normal orbits bilaterally were included in this study. The cut in which the lateral rectus muscle was longest and the lateral bony orbit was thickest was selected from the axial and coronal slices. The point where the lateral rectus muscle contacted the the bone was measured on this axial slice. The width of the lateral wall was measured at the level of superior border of the lateral rectus muscle on thickest part of the coronal slice. Results: A total of 334 orbits (167 patients) were included. Patients ranged in age from 7 years to 78 years (median age 41.1 years). The average distance of the lateral wall was 26.0 mm OD and 25.0 mm OS. The average width of the lateral wall was 16.0 mm OD 16.2 mm OS. There was no statistically significant difference between right and left. The patients were divided into 8 age groups by decades. There was no statistically significant difference between the groups in either measurement. Conclusion: In this study, we measured the average width and length of the thickest segment of the greater wing of the sphenoid, which can be used as anatomic guidelines during deep lateral orbital decompression surgery, and the basic standard value of the lateral orbital wall. (C) 2011 European Association for Cranio-Maxillo-Facial Surgery.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Hen photo

Lee, Young Hen
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE