Measurement of Ion Kinetic-energy Distributions in Electron-impact Ion Sources of a Quadrupole Mass Spectrometer
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ahn, Jong Rok | - |
dc.contributor.author | Lee, Soon-Gul | - |
dc.contributor.author | Park, Chang Joon | - |
dc.date.accessioned | 2021-09-07T08:03:23Z | - |
dc.date.available | 2021-09-07T08:03:23Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2011-10 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/111542 | - |
dc.description.abstract | An ideal ion source should create stable ion beams of sufficient intensity with an ion energy spread as low as possible. Most electron-impact ion sources used in mass spectrometers have been based on the design by Nier. Calculation of the potential distribution in the ion source revealed that the ion extraction efficiency could be improved by applying a positive repeller potential to the ionization chamber, which is normally at ground potential in a Nier-type ion source. Ion kinetic-energy distributions were measured in a Nier-type ion source and in a modified ion source by applying a retarding pole bias potential to the quadrupole at various emission currents and chamber pressures. As the emission current or the chamber pressure was increased, the most probable energy was shifted to a higher energy in both ion sources. However, the ion kinetic-energy spread was smaller and varied less in the modified ion source while it was larger in the conventional Nier-type ion source. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.title | Measurement of Ion Kinetic-energy Distributions in Electron-impact Ion Sources of a Quadrupole Mass Spectrometer | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Soon-Gul | - |
dc.identifier.doi | 10.3938/jkps.59.2670 | - |
dc.identifier.scopusid | 2-s2.0-80054885270 | - |
dc.identifier.wosid | 000295915500004 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.59, no.4, pp.2670 - 2675 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 59 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 2670 | - |
dc.citation.endPage | 2675 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001596094 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordAuthor | Ion source | - |
dc.subject.keywordAuthor | Computer simulation of ion trajectories | - |
dc.subject.keywordAuthor | Ion kinetic-energy distribution | - |
dc.subject.keywordAuthor | Retarding pole bias potential | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.