Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Jong Min | - |
dc.contributor.author | Lee, Chulho | - |
dc.contributor.author | Park, Moonseo | - |
dc.contributor.author | Kang, Shin-Hyung | - |
dc.contributor.author | Choi, Hangseok | - |
dc.date.accessioned | 2021-09-07T11:07:56Z | - |
dc.date.available | 2021-09-07T11:07:56Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2011-07 | - |
dc.identifier.issn | 1674-7321 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/112126 | - |
dc.description.abstract | In this study, a series of numerical analyses was performed in order to evaluate the performance of full-scale closed-loop vertical ground heat exchangers constructed in Wonju, South Korea. The circulating HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the ground heat exchanger system. Two user-defined functions (UDFs) accounting for the difference in the temperature of the circulating inflow and outflow fluid and the variation of ground temperature with depth were adopted in the FLUENT modeling. The thermal conductivities of grouts (cement vs. bentonite) measured in laboratory were used as input values in the numerical analyses to compare the thermal efficiency of the cement and bentonite grouts used for installing the closed-loop vertical ground heat exchanger. A series of numerical analyses was carried out to simulate in-situ thermal response tests performed in the construction site. From the comparison between the in-situ thermal response test results and numerical simulations, the average thermal conductivity of the ground formation in the construction site is back-calculated as approximately 4 W/mK. This value can be used in evaluating the long-term performance of the closed-loop vertical ground heat exchanger. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SCIENCE PRESS | - |
dc.title | Numerical simulation for thermal response test performance in closed-loop vertical ground heat exchanger | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Hangseok | - |
dc.identifier.doi | 10.1007/s11431-011-4389-x | - |
dc.identifier.scopusid | 2-s2.0-80051579082 | - |
dc.identifier.wosid | 000292828100004 | - |
dc.identifier.bibliographicCitation | SCIENCE CHINA-TECHNOLOGICAL SCIENCES, v.54, no.7, pp.1668 - 1673 | - |
dc.relation.isPartOf | SCIENCE CHINA-TECHNOLOGICAL SCIENCES | - |
dc.citation.title | SCIENCE CHINA-TECHNOLOGICAL SCIENCES | - |
dc.citation.volume | 54 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 1668 | - |
dc.citation.endPage | 1673 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.subject.keywordAuthor | closed-loop vertical ground heat exchanger | - |
dc.subject.keywordAuthor | cement grout | - |
dc.subject.keywordAuthor | bentonite grout | - |
dc.subject.keywordAuthor | in-situ thermal response test | - |
dc.subject.keywordAuthor | finite-volume method | - |
dc.subject.keywordAuthor | thermal conductivity | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.