Applicability of cement-based grout for ground heat exchanger considering heating-cooling cycles
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Moonseo | - |
dc.contributor.author | Min, Sunhong | - |
dc.contributor.author | Lim, Jeehee | - |
dc.contributor.author | Choi, Jong Min | - |
dc.contributor.author | Choi, Hangseok | - |
dc.date.accessioned | 2021-09-07T11:16:17Z | - |
dc.date.available | 2021-09-07T11:16:17Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2011-07 | - |
dc.identifier.issn | 1674-7321 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/112172 | - |
dc.description.abstract | The applicability of cement grout (or cement-based grout) has been considered as an alternative to bentonite grout commonly used to backfill closed-loop vertical ground heat exchangers. In a geothermal heat pump system, repeated heating-cooling cycles may cause adverse effects on the integrity of cement grout in the ground heat exchanger. To account for the temperature cycling effect, the strength degradation of cement grout due to temperature cycling has been examined by measuring the unconfined compression strength of cured specimens in a humidity-temperature controlling chamber with applying temperature cycles between -5A degrees C and 50A degrees C. There is a tendency that the unconfined compression strength decreases with an increase in the number of temperature cycles. On the other hand, an equivalent hydraulic conductivity of a pipe-embedded cement grout specimen was evaluated by carrying out a modified flexible wall permeameter test equipped with a water circulating system to control temperature inside the pipe section. The applied operating temperature range was from 5 to 35A degrees C. After three cycles of heating-cooling circulation, the equivalent hydraulic conductivity becomes asymptotic to a constant value, which implies there is no severe detachment of the pipe from the cement grout. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SCIENCE PRESS | - |
dc.title | Applicability of cement-based grout for ground heat exchanger considering heating-cooling cycles | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Hangseok | - |
dc.identifier.doi | 10.1007/s11431-011-4388-y | - |
dc.identifier.scopusid | 2-s2.0-80051579205 | - |
dc.identifier.wosid | 000292828100003 | - |
dc.identifier.bibliographicCitation | SCIENCE CHINA-TECHNOLOGICAL SCIENCES, v.54, no.7, pp.1661 - 1667 | - |
dc.relation.isPartOf | SCIENCE CHINA-TECHNOLOGICAL SCIENCES | - |
dc.citation.title | SCIENCE CHINA-TECHNOLOGICAL SCIENCES | - |
dc.citation.volume | 54 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 1661 | - |
dc.citation.endPage | 1667 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.subject.keywordAuthor | cement grout | - |
dc.subject.keywordAuthor | bentonite grout | - |
dc.subject.keywordAuthor | thermal conductivity | - |
dc.subject.keywordAuthor | workability | - |
dc.subject.keywordAuthor | equivalent permeability coefficient | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.