A Durability Study of a Paracorporeal Pulsatile Electro-Mechanical Pneumatic Biventricular Assist Device

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Hyuk-
dc.contributor.authorLee, Heung-Man-
dc.contributor.authorNam, Kyoung Won-
dc.contributor.authorChoi, Jaesoon-
dc.contributor.authorLee, Jung-Joo-
dc.contributor.authorKim, Ho Chul-
dc.contributor.authorSong, Seung Joon-
dc.contributor.authorAhn, Chi Bum-
dc.contributor.authorSon, Ho Sung-
dc.contributor.authorLim, Choon Hak-
dc.contributor.authorSon, Kuk Hui-
dc.contributor.authorPark, Yong Doo-
dc.contributor.authorJeong, Gi Seok-
dc.contributor.authorSun, Kyung-
dc.date.accessioned2021-09-07T12:03:10Z-
dc.date.available2021-09-07T12:03:10Z-
dc.date.created2021-06-14-
dc.date.issued2011-06-
dc.identifier.issn0160-564X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/112344-
dc.description.abstractIn 2002, the paracorporeal pulsatile electromechanical pneumatic ventricular assist device (VAD) began to be developed by the Korea Artificial Organ Center at Korea University under a Health & Medical Technology Research and Development program which finished in 2008. In vitro durability testing was conducted on the paracorporeal pulsatile pneumatic VAD to determine device durability and to evaluate device failures. The 1- and 2-year reliability of the paracorporeal pulsatile pneumatic VAD was shown to be 91.2% and 54.9%, respectively, with an 80% confidence level. Failure modes were analyzed using fault tree analysis, with customized software continuously acquiring data during the test period. After this period, 21 in vivo animal tests were done, with 14 cases of left atrium to left ventricle (LV) inflow cannulation (36Fr)/outflow grafting to descending aorta, and seven cases of apex cannulation of LV to descending aorta (12 mm). The longest postoperative day (182 days) in Korea was recently recorded in in vivo animal testing (bovine, 90 kg, male, 3.5-4.0 L/min flow rate, and 55 bpm).-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectFAULT-TREE ANALYSIS-
dc.subjectPORTABLE DRIVER-
dc.subjectSUPPORT-SYSTEM-
dc.subjectRELIABILITY-
dc.subjectFAILURE-
dc.subjectENERGY-
dc.subjectRISK-
dc.titleA Durability Study of a Paracorporeal Pulsatile Electro-Mechanical Pneumatic Biventricular Assist Device-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hyuk-
dc.contributor.affiliatedAuthorLee, Heung-Man-
dc.contributor.affiliatedAuthorChoi, Jaesoon-
dc.contributor.affiliatedAuthorLee, Jung-Joo-
dc.contributor.affiliatedAuthorAhn, Chi Bum-
dc.contributor.affiliatedAuthorSon, Ho Sung-
dc.contributor.affiliatedAuthorLim, Choon Hak-
dc.contributor.affiliatedAuthorPark, Yong Doo-
dc.contributor.affiliatedAuthorJeong, Gi Seok-
dc.contributor.affiliatedAuthorSun, Kyung-
dc.identifier.doi10.1111/j.1525-1594.2010.01187.x-
dc.identifier.scopusid2-s2.0-79958776864-
dc.identifier.wosid000291936700009-
dc.identifier.bibliographicCitationARTIFICIAL ORGANS, v.35, no.6, pp.614 - 624-
dc.relation.isPartOfARTIFICIAL ORGANS-
dc.citation.titleARTIFICIAL ORGANS-
dc.citation.volume35-
dc.citation.number6-
dc.citation.startPage614-
dc.citation.endPage624-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.subject.keywordPlusFAULT-TREE ANALYSIS-
dc.subject.keywordPlusPORTABLE DRIVER-
dc.subject.keywordPlusSUPPORT-SYSTEM-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordPlusFAILURE-
dc.subject.keywordPlusENERGY-
dc.subject.keywordPlusRISK-
dc.subject.keywordAuthorParacorporeal pulsatile electro-mechanical pneumatic ventricular assist device-
dc.subject.keywordAuthorReliability test-
dc.subject.keywordAuthordurability-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hyuk photo

Choi, Hyuk
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE