Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance characteristics of a simultaneous cooling and heating multi-heat pump at partial load conditions

Full metadata record
DC Field Value Language
dc.contributor.authorJoo, Youngju-
dc.contributor.authorKang, Hoon-
dc.contributor.authorAhn, Jae Hwan-
dc.contributor.authorLee, Mooyeon-
dc.contributor.authorKim, Yongchan-
dc.date.accessioned2021-09-07T12:10:31Z-
dc.date.available2021-09-07T12:10:31Z-
dc.date.created2021-06-14-
dc.date.issued2011-06-
dc.identifier.issn0140-7007-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/112384-
dc.description.abstractA simultaneous cooling and heating multi-heat pump can improve thermal comfort and energy efficiency through heat recovery at partial load conditions. The performance of a simultaneous heating and cooling multi-heat pump with four indoor units was measured by varying the compressor speed, EEV opening, and fan speed at full and partial load conditions in five operating modes. In the cooling-only and heating-only modes, the heating and cooling capacities were properly controlled by varying the compressor speed. However, in the cooling-main and heating-main modes under partial load conditions, a large imbalance between the cooling and heating capacities was observed even though the compressor speed was optimized. This capacity imbalance under partial load conditions was optimized by adjusting the EEV openings in the mode change unit and the outdoor unit. In addition, in the entire-heat recovery mode, rating compressor speed ratios were proposed under the full and partial load conditions. (C) 2011 Elsevier Ltd and IIR. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.subjectAIR-CONDITIONER-
dc.titlePerformance characteristics of a simultaneous cooling and heating multi-heat pump at partial load conditions-
dc.typeArticle-
dc.contributor.affiliatedAuthorKang, Hoon-
dc.contributor.affiliatedAuthorKim, Yongchan-
dc.identifier.doi10.1016/j.ijrefrig.2010.12.025-
dc.identifier.scopusid2-s2.0-79955924605-
dc.identifier.wosid000291576500009-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, v.34, no.4, pp.893 - 901-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID-
dc.citation.titleINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID-
dc.citation.volume34-
dc.citation.number4-
dc.citation.startPage893-
dc.citation.endPage901-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.subject.keywordPlusAIR-CONDITIONER-
dc.subject.keywordAuthorHeat pump-
dc.subject.keywordAuthorHeat recovery-
dc.subject.keywordAuthorVariable speed-
dc.subject.keywordAuthorElectronic expansion valve-
dc.subject.keywordAuthorR410A-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE