Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The flexible Ca-test: An improved performance in a gas permeability measurement system

Full metadata record
DC Field Value Language
dc.contributor.authorSong, Eun Ho-
dc.contributor.authorPark, Young Wook-
dc.contributor.authorChoi, Jin Hwan-
dc.contributor.authorPark, Tae Hyun-
dc.contributor.authorJeong, Jin Wook-
dc.contributor.authorChoi, Hyun Ju-
dc.contributor.authorJu, Byeong Kwon-
dc.date.accessioned2021-09-07T13:01:11Z-
dc.date.available2021-09-07T13:01:11Z-
dc.date.created2021-06-14-
dc.date.issued2011-05-
dc.identifier.issn0034-6748-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/112594-
dc.description.abstractA flexible performance permeability measuring test for flexible organic light-emitting diodes is described in this paper. A single thin film layer of gas barriers is constructed on polyethersulfone (PES). The barrier coats the upper and lower surfaces of the PES layer. Two PES samples, one coated with Al2O3 on both surfaces and the other coated on a single surface, were made for comparison. According to this test, the time-dependent transmission curve of the one sided barrier sample had a linear slope which measured 1.65 g/m(2)/day at room temperature at a 50% relative humidity. This result shows that the measurement time is about 182% faster than has been achieved with the conventional test structure that uses a glass substrate. In addition, this measurement structure not only reduces the inevitable electrical noise which occurs during measurement but also increases the water vapor permeation signal. These effects improve the sensing reliability of the test. In addition, this structure is flexible, so one can instantly detect barrier performance changes when applying external stress. (C) 2011 American Institute of Physics. [doi:10.1063/1.3584903]-
dc.languageEnglish-
dc.language.isoen-
dc.publisherAMER INST PHYSICS-
dc.subjectLIGHT-EMITTING DEVICES-
dc.subjectBARRIER TECHNOLOGY-
dc.subjectVAPOR PERMEATION-
dc.subjectWATER-VAPOR-
dc.subjectMECHANISMS-
dc.subjectDISPLAYS-
dc.subjectDIODES-
dc.titleThe flexible Ca-test: An improved performance in a gas permeability measurement system-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Young Wook-
dc.contributor.affiliatedAuthorJu, Byeong Kwon-
dc.identifier.doi10.1063/1.3584903-
dc.identifier.scopusid2-s2.0-79958051535-
dc.identifier.wosid000291106700042-
dc.identifier.bibliographicCitationREVIEW OF SCIENTIFIC INSTRUMENTS, v.82, no.5-
dc.relation.isPartOfREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.citation.titleREVIEW OF SCIENTIFIC INSTRUMENTS-
dc.citation.volume82-
dc.citation.number5-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusLIGHT-EMITTING DEVICES-
dc.subject.keywordPlusBARRIER TECHNOLOGY-
dc.subject.keywordPlusVAPOR PERMEATION-
dc.subject.keywordPlusWATER-VAPOR-
dc.subject.keywordPlusMECHANISMS-
dc.subject.keywordPlusDISPLAYS-
dc.subject.keywordPlusDIODES-
dc.subject.keywordAuthorFlexible electronics-
dc.subject.keywordAuthorGas permeability measurement-
dc.subject.keywordAuthorBarrier layer-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ju, Byeong kwon photo

Ju, Byeong kwon
공과대학 (전기전자공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE