Scintillation-Fiber Detection for Dose Verification in Hadron Therapy
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Kyong Sei | - |
dc.contributor.author | Hong, Byungsik | - |
dc.contributor.author | Jhang, Genie | - |
dc.contributor.author | Ju, Euna | - |
dc.contributor.author | Kim, Chong | - |
dc.contributor.author | Park, Sungkeun | - |
dc.contributor.author | Rhee, Han Bum | - |
dc.contributor.author | Shim, Hyun Ha | - |
dc.contributor.author | Sim, Kwang-Souk | - |
dc.date.accessioned | 2021-09-07T13:50:05Z | - |
dc.date.available | 2021-09-07T13:50:05Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2011-04 | - |
dc.identifier.issn | 0374-4884 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/112807 | - |
dc.description.abstract | In this paper, we report on the development of a scintillation-fiber detection method for close verification in hadron therapy. In order to achieve the position sensitivity required for precision measurement of closes, a detector composed of 1-mm-thick scintillation fibers and a multi-channel photodiode was constructed and tested with 45-MeV proton beams provided by the MC50 proton cyclotron at the Korea Institute of Radiological and Medical Science (KIRAMS). The results of the beam test showed that the spatial resolution of the data determined by using the standard deviation sigma was similar to 1.0 mm, which is sufficiently accurate to verify beam-induced doses in hadron therapy. Furthermore, the quantitative accuracy appearing in the data is on the order of similar to 1%. We expect the detector composed of scintillation fibers and operating in the charge-integration mode to allow us to perform quality measurement of doses in various hadron therapies. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN PHYSICAL SOC | - |
dc.subject | HEAVY-ION RADIOTHERAPY | - |
dc.subject | BEAM | - |
dc.subject | SYSTEM | - |
dc.title | Scintillation-Fiber Detection for Dose Verification in Hadron Therapy | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Kyong Sei | - |
dc.contributor.affiliatedAuthor | Hong, Byungsik | - |
dc.contributor.affiliatedAuthor | Park, Sungkeun | - |
dc.contributor.affiliatedAuthor | Sim, Kwang-Souk | - |
dc.identifier.doi | 10.3938/jkps.58.706 | - |
dc.identifier.scopusid | 2-s2.0-79955067964 | - |
dc.identifier.wosid | 000289611500004 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.58, no.4, pp.706 - 712 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.title | JOURNAL OF THE KOREAN PHYSICAL SOCIETY | - |
dc.citation.volume | 58 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 706 | - |
dc.citation.endPage | 712 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001544973 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Multidisciplinary | - |
dc.subject.keywordPlus | HEAVY-ION RADIOTHERAPY | - |
dc.subject.keywordPlus | BEAM | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordAuthor | Hadron therapy | - |
dc.subject.keywordAuthor | Bragg distribution | - |
dc.subject.keywordAuthor | GEANT4 | - |
dc.subject.keywordAuthor | Dose verification | - |
dc.subject.keywordAuthor | Scintillation fiber | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.