Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Determination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Byung-Kwon-
dc.contributor.authorXue, Shubin-
dc.contributor.authorNam, Jeonghun-
dc.contributor.authorLim, Hyunjung-
dc.contributor.authorShin, Sehyun-
dc.date.accessioned2021-09-07T14:29:23Z-
dc.date.available2021-09-07T14:29:23Z-
dc.date.created2021-06-14-
dc.date.issued2011-03-
dc.identifier.issn1226-119X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/112916-
dc.description.abstractWe investigated the applicability of two non-Newtonian constitutive models (Casson and Herschel-Bulkley models) in the determination of the blood viscosity and yield stress using a pressure-scanning microfluidic hemorheometer. The present results were compared with the measurements through a precision rheometer (ARES2). For a Newtonian fluid (standard oil), the two constitutive models showed excellent agreement with a reference value and the measurement of ARES2. For human blood as a non-Newtonian fluid, both the Casson and Herschel-Bulkley models exhibited similar viscosity results over a range of shear rates and showed excellent agreement with the ARES2 results. The Herschel-Bulkley model yielded a slightly higher value than other results at low shear rates ((gamma) over dot < 10), which may be due to the relatively high value of the yield stress. The yield stress values for whole blood were 14.4 mPa for the Casson model and 32.5 mPa for the Herschel-Bulkley model, respectively. Thus, the present study showed that the Casson model would be better than the Herschel-Bulkley model for representing the non-Newtonian characteristics of blood viscosity.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN SOC RHEOLOGY-
dc.subjectSHEAR-
dc.subjectVISCOMETER-
dc.subjectTUBE-
dc.subjectHEMATOCRIT-
dc.subjectDEPENDENCE-
dc.titleDetermination of the blood viscosity and yield stress with a pressure- scanning capillary hemorheometer using constitutive models-
dc.typeArticle-
dc.contributor.affiliatedAuthorShin, Sehyun-
dc.identifier.doi10.1007/s13367-011-0001-y-
dc.identifier.scopusid2-s2.0-79959821628-
dc.identifier.wosid000289120100001-
dc.identifier.bibliographicCitationKOREA-AUSTRALIA RHEOLOGY JOURNAL, v.23, no.1, pp.1 - 6-
dc.relation.isPartOfKOREA-AUSTRALIA RHEOLOGY JOURNAL-
dc.citation.titleKOREA-AUSTRALIA RHEOLOGY JOURNAL-
dc.citation.volume23-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage6-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001537296-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalResearchAreaPolymer Science-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.relation.journalWebOfScienceCategoryPolymer Science-
dc.subject.keywordPlusSHEAR-
dc.subject.keywordPlusVISCOMETER-
dc.subject.keywordPlusTUBE-
dc.subject.keywordPlusHEMATOCRIT-
dc.subject.keywordPlusDEPENDENCE-
dc.subject.keywordAuthorblood viscosity-
dc.subject.keywordAuthoryield stress-
dc.subject.keywordAuthorcapillary viscometer-
dc.subject.keywordAuthorcasson-
dc.subject.keywordAuthorherschel-bulkley-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Shin, Se hyun photo

Shin, Se hyun
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE