Comparative Analysis of Radiation Dose and Image Quality Between Thyroid Shielding and Unshielding During CT Examination of the Neck

Authors
Lee, Young HenPark, Eun-taeCho, Pyong KonSeo, Hyung SukJe, Bo-KyungSuh, Sang-ilYang, Kyung-Sook
Issue Date
3월-2011
Publisher
AMER ROENTGEN RAY SOC
Keywords
bismuth shielding; CT; radiation dose
Citation
AMERICAN JOURNAL OF ROENTGENOLOGY, v.196, no.3, pp.611 - 615
Indexed
SCIE
SCOPUS
Journal Title
AMERICAN JOURNAL OF ROENTGENOLOGY
Volume
196
Number
3
Start Page
611
End Page
615
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/112956
DOI
10.2214/AJR.10.4955
ISSN
0361-803X
Abstract
OBJECTIVE. The purpose of this study is to evaluate the feasibility of thyroid shielding by measuring radiation dose, CT attenuation, and noise of superficial neck structures during CT examination. SUBJECTS AND METHODS. We divided 84 patients without abnormalities seen on CT into two groups depending on whether shielding with a cotton spacer was applied over the thyroid. On CT images, we measured the CT attenuation and noises in the strap and sternocleidomastoid (SCM) muscles. The superficial radiation dose was measured using a head CT dose phantom containing ionization chambers located at the 3, 6, 9, and 12 o'clock positions. RESULTS. With thyroid shielding, the CT attenuation was significantly increased (shielded strap and SCM muscles, 117.6 +/- 19.2 HU and 113.7 +/- 31.8 HU, respectively; unshielded strap and SCM muscles, 84.1 +/- 12.2 HU and 78.4 +/- 10.1 HU, respectively; p < 0.05), whereas noise was unaffected (shielded strap and SCM muscles, 7.2 +/- 4.2 HU and 10.8 +/- 4.9 HU, respectively; unshielded strap and SCM muscles, 8.6 +/- 4.9 HU and 10.7 +/- 6.6 HU, respectively; p > 0.05). On the phantom study, the shield significantly reduced the superficial unshielded dose at the 12 o'clock position only (27.5% reduction; p < 0.01). CONCLUSION. Below the shielded surface, thyroid shielding significantly reduced the superficial radiation dose of the neck without a remarkable noise increase while increasing CT attenuation.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Je, Bo Kyung photo

Je, Bo Kyung
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE