Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of soft-tissue serum markers in stable intertrochanteric fracture: Dynamic hip screw versus proximal femoral nail-A preliminary study

Full metadata record
DC Field Value Language
dc.contributor.authorHong, Jae-Young-
dc.contributor.authorSuh, Seung-Woo-
dc.contributor.authorPark, Jung-Ho-
dc.contributor.authorShin, Young-Soo-
dc.contributor.authorYoon, Jung-Ro-
dc.contributor.authorYang, Jae-Hyuk-
dc.date.accessioned2021-09-07T15:38:11Z-
dc.date.available2021-09-07T15:38:11Z-
dc.date.created2021-06-14-
dc.date.issued2011-02-
dc.identifier.issn0020-1383-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/113160-
dc.description.abstractDesign: Prospective randomised comparative study. Objectives: To analyse and compare serum soft-tissue marker differences after dynamic hip screw (DHS) and proximal femoral nail (PFN) fixation of stable intertrochanteric fractures in the elderly. Materials and methods: Twenty elderly patients (>60 years old) with a stable intertrochanteric fracture were enrolled in this study. Patients were divided into two groups of 10 each according to the device used (DHS or PFN). All 20 patients had a stable intertrochanteric fracture, and all were operated on by the same surgeon using minimal invasive approach. A biochemical comparison of soft-tissue serum markers was performed. The serum markers examined were haemoglobin (Hb), haematocrit (Hct), creatine kinase (CK), myoglobin (MYO), troponin I and C-reactive protein (CRP), and their levels were determined before surgery, and 1, 8, 16, 24, 36, 48 and 72 h after surgery. Differences between the DHS and PFN groups were compared. Results: No inter-group differences were observed with respect to preoperative demographics, operation time, incision length or blood loss. In terms of serum markers, both methods showed similar patterns of change for CK, MYO and CRP pre- to post-operatively. In addition, pre- and postoperative Hb and Hct levels were similar. Furthermore, no inter-group differences were observed between the absolute values of serum markers at any point. Conclusion: The absolute values and temporal changes of serum markers were similar in the two study groups. These findings suggest that DHS and PFN fixation of stable intertrochanteric fractures produce similar levels of soft-tissue damage. (C) 2010 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.subjectINTRAMEDULLARY NAIL-
dc.subjectTROCHANTERIC FRACTURES-
dc.subjectFIXATION-
dc.subjectFEMUR-
dc.subjectSURGERY-
dc.subjectPLATE-
dc.subjectTRIAL-
dc.subjectCOMPLICATIONS-
dc.subjectMETAANALYSIS-
dc.subjectMYOGLOBIN-
dc.titleComparison of soft-tissue serum markers in stable intertrochanteric fracture: Dynamic hip screw versus proximal femoral nail-A preliminary study-
dc.typeArticle-
dc.contributor.affiliatedAuthorHong, Jae-Young-
dc.contributor.affiliatedAuthorSuh, Seung-Woo-
dc.contributor.affiliatedAuthorPark, Jung-Ho-
dc.identifier.doi10.1016/j.injury.2010.09.008-
dc.identifier.scopusid2-s2.0-78651479976-
dc.identifier.wosid000286135100019-
dc.identifier.bibliographicCitationINJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, v.42, no.2, pp.204 - 208-
dc.relation.isPartOfINJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED-
dc.citation.titleINJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED-
dc.citation.volume42-
dc.citation.number2-
dc.citation.startPage204-
dc.citation.endPage208-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalResearchAreaEmergency Medicine-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryCritical Care Medicine-
dc.relation.journalWebOfScienceCategoryEmergency Medicine-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusINTRAMEDULLARY NAIL-
dc.subject.keywordPlusTROCHANTERIC FRACTURES-
dc.subject.keywordPlusFIXATION-
dc.subject.keywordPlusFEMUR-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusPLATE-
dc.subject.keywordPlusTRIAL-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusMETAANALYSIS-
dc.subject.keywordPlusMYOGLOBIN-
dc.subject.keywordAuthorSoft-tissue serum markers-
dc.subject.keywordAuthorIntertrochanteric fracture-
dc.subject.keywordAuthorDynamic hip screw-
dc.subject.keywordAuthorProximal femoral nail-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jung Ho photo

Park, Jung Ho
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE