Application of 3-Dimensional Ultrasonography in Assessing Carpal Tunnel Syndrome
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Pyun, Sung Bum | - |
dc.contributor.author | Kang, Chang Ho | - |
dc.contributor.author | Yoon, Joon Shik | - |
dc.contributor.author | Kwon, Hee Kyu | - |
dc.contributor.author | Kim, Jung Hyuk | - |
dc.contributor.author | Chung, Kyoo Byung | - |
dc.contributor.author | Oh, Yu Whan | - |
dc.date.accessioned | 2021-09-07T16:40:28Z | - |
dc.date.available | 2021-09-07T16:40:28Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2011-01 | - |
dc.identifier.issn | 0278-4297 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/113411 | - |
dc.description.abstract | Objectives-The aim of study was to assess the usefulness of 3D ultrasonography (3DUS) in the diagnosis of carpal tunnel syndrome. Methods-Fifty patients with carpal tunnel syndrome confirmed by electromyography and 37 healthy control participants underwent 3DUS of the wrists. The mean times per participant for the 3DUS examination and review of the 3D volume set were recorded. The cross-sectional area at the proximal carpal tunnel and the maximum swelling point were measured. Data from patients and controls were compared for determination of statistical significance. The accuracy of the 3DUS diagnostic criteria for carpal tunnel syndrome was evaluated using receiver operating characteristic analysis, and changes in the median nerve shape, including the maximum swelling point, were assessed by review of the 3D volume data. Results-The mean times for examination of a participant and review in each wrist were 56 seconds and 5.7 minutes, respectively. Significant differences were observed in the mean cross-sectional areas of the median nerve between patients and controls. The mean cross-sectional areas +/- SD were 16.7 +/- 6.7 mm(2) in patients and 8.3 +/- 1.9 mm(2) in controls. Using the receiver operating characteristic curve, a cutoff value of greater than 10.5 mm(2) provided diagnostic sensitivity of 84% and specificity of 86%. In 42 of 73 wrists with carpal tunnel syndrome, the median nerve showed fusiform morphologic abnormalities and maximum swelling points. Conclusions-Our results show that 3DUS could markedly decrease scanning time, and measurement of the median nerve cross-sectional area combined with morphologic analysis using 3DUS is a promising supplementary method for the diagnosis of carpal tunnel syndrome. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | HIGH-RESOLUTION SONOGRAPHY | - |
dc.subject | MEDIAN NERVE | - |
dc.subject | DIAGNOSIS | - |
dc.subject | ULTRASOUND | - |
dc.subject | CRITERIA | - |
dc.subject | HANDS | - |
dc.subject | US | - |
dc.title | Application of 3-Dimensional Ultrasonography in Assessing Carpal Tunnel Syndrome | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Pyun, Sung Bum | - |
dc.contributor.affiliatedAuthor | Kang, Chang Ho | - |
dc.contributor.affiliatedAuthor | Yoon, Joon Shik | - |
dc.contributor.affiliatedAuthor | Kwon, Hee Kyu | - |
dc.contributor.affiliatedAuthor | Kim, Jung Hyuk | - |
dc.contributor.affiliatedAuthor | Chung, Kyoo Byung | - |
dc.contributor.affiliatedAuthor | Oh, Yu Whan | - |
dc.identifier.doi | 10.7863/jum.2011.30.1.3 | - |
dc.identifier.scopusid | 2-s2.0-78650871112 | - |
dc.identifier.wosid | 000287009000002 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ULTRASOUND IN MEDICINE, v.30, no.1, pp.3 - 10 | - |
dc.relation.isPartOf | JOURNAL OF ULTRASOUND IN MEDICINE | - |
dc.citation.title | JOURNAL OF ULTRASOUND IN MEDICINE | - |
dc.citation.volume | 30 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 3 | - |
dc.citation.endPage | 10 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Acoustics | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Acoustics | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | HIGH-RESOLUTION SONOGRAPHY | - |
dc.subject.keywordPlus | MEDIAN NERVE | - |
dc.subject.keywordPlus | DIAGNOSIS | - |
dc.subject.keywordPlus | ULTRASOUND | - |
dc.subject.keywordPlus | CRITERIA | - |
dc.subject.keywordPlus | HANDS | - |
dc.subject.keywordPlus | US | - |
dc.subject.keywordAuthor | carpal tunnel syndrome | - |
dc.subject.keywordAuthor | median nerve | - |
dc.subject.keywordAuthor | 3-dimensional ultrasonography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.