Diagnosing Small Hepatic Cysts on Multidetector CT: an Additional Merit of Thinner Coronal Reformations

Full metadata record
DC Field Value Language
dc.contributor.author황성호-
dc.contributor.author유정식-
dc.contributor.author정재준-
dc.contributor.author김주희-
dc.contributor.author김기황-
dc.date.accessioned2021-09-07T17:41:18Z-
dc.date.available2021-09-07T17:41:18Z-
dc.date.created2021-06-17-
dc.date.issued2011-
dc.identifier.issn1229-6929-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/113738-
dc.description.abstractObjective: We wanted to validate the additional merit of the thinner coronal reformation images from multidetector CT (MDCT) for making the diagnosis of hepatic cysts. Materials and Methods: For the 90 benign hepatic cysts confirmed on MRI, the transverse (5-mm thickness) and additional coronal (2-mm thickness) reformation images from MDCT were compared with each other in terms of the Hounsfield units (HUs) and the size of each hepatic cyst. Results: The attenuations (mean: 17.2 HUs, standard deviation: ± 14.4) on the thinner coronal images were significantly lower than those (mean: 40.7 HUs; standard deviation: ± 20.6) on the thicker transverse images for the small hepatic cysts (≤ 10 mm on the transverse image, p < 0.01). Twenty-three (79%) of the 29 cysts between 5 mm and 10 mm and 21 (51%) of 41 lesions up to 5 mm showed a mean HU value of 20 or less on the coronal reformation images. Conclusion: By reducing the partial volume effect, routine coronal reformation of MDCT with a thinner section thickness can provide another merit for making a confidential diagnosis of many small sub-centimeter hepatic cysts, and these small cysts are not easily characterized on the conventional transverse images.-
dc.languageEnglish-
dc.language.isoen-
dc.publisher대한영상의학회-
dc.titleDiagnosing Small Hepatic Cysts on Multidetector CT: an Additional Merit of Thinner Coronal Reformations-
dc.title.alternativeDiagnosing Small Hepatic Cysts on Multidetector CT: an Additional Merit of Thinner Coronal Reformations-
dc.typeArticle-
dc.contributor.affiliatedAuthor황성호-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.12, no.3, pp.341 - 350-
dc.relation.isPartOfKorean Journal of Radiology-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume12-
dc.citation.number3-
dc.citation.startPage341-
dc.citation.endPage350-
dc.type.rimsART-
dc.identifier.kciidART001556932-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorMultidetector CT (MDCT)-
dc.subject.keywordAuthorHepatic cyst-
dc.subject.keywordAuthorHounsfield units (HUs)-
dc.subject.keywordAuthorSectional thickness-
dc.subject.keywordAuthorPartial volume effect-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE