dc.description.abstractPURPOSE: This study was aimed to compare the margin and internal fitness of 3-unit zirconia bridge cores fabricated by several CAD/CAM systems using replica technique. MATERIALS AND METHODS: Three unit-bridge models in which upper canine and upper second premolar were used as abutments and upper first premolar was missed, were fabricated. Fourty models were classified into 4 groups (Cerasys® (Group C), Dentaim® (Group D), KaVo Everest® (Group K), Lava™ (Group L)), and zirconia cores were fabricated by each company. Sixteen points were measured on each abutment by replica technique. Statistical analysis was accomplished with two way ANOVA and Dunnett T3(α=.05). RESULTS: In most systems, there was a larger gap on inter margin than outer margin. In the Group K, overall fitness was excellent, but the incisal gap was very large. In the Group C, marginal gap was significantly larger than Group K, but overall internal gap was uniform (P<.05). The axial gap was under 100 μm in all system. The difference between internal and external gap was small on Group L and C. However, internal gap was significantly larger than external gap in Group D (P<.05). The fitness of canine was better than second premolar among abutments (P<.05). CONCLUSION: The marginal and internal gap was within the clinically allowed range in all of the three systems. There was a larger gap on second premolar than canine on internal and marginal surface. In most systems, there was a larger gap on occlusal surface than axial surface.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한치과보철학회-
dc.title다양한CAD/CAM 시스템으로 제작된 3 본 고정성 가공의치 지르코니아 코어의 변연 및 내면 적합도 평가-
dc.title.alternativeMarginal and internal fitness of three-unit zirconia cores fabricated using several CAD/CAM systems-
dc.typeArticle-
dc.contributor.affiliatedAuthor김종은-
dc.contributor.affiliatedAuthor이정열-
dc.contributor.affiliatedAuthor김영수-
dc.contributor.affiliatedAuthor신상완-
dc.identifier.doi10.4047/jkap.2011.49.3.236-
dc.identifier.bibliographicCitation대한치과보철학회지, v.49, no.03, pp.236 - 244-
dc.relation.isPartOf대한치과보철학회지-
dc.citation.title대한치과보철학회지-
dc.citation.volume49-
dc.citation.number03-
dc.citation.startPage236-
dc.citation.endPage244-
dc.type.rimsART-
dc.identifier.kciidART001572794-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor변연 적합도-
dc.subject.keywordAuthor내면 적합도-
dc.subject.keywordAuthorCAD/CAM-
dc.subject.keywordAuthor지르코니아 코어-
dc.subject.keywordAuthorMarginal fitness-
dc.subject.keywordAuthorInternal fitness-
dc.subject.keywordAuthorCAD/CAM-
dc.subject.keywordAuthorZirconia core-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE