Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

베네시안 블라인드가 적용된 창호 시스템의 1차 투과율 평가를 위한 에너지 플러스 알고리즘과 DIN EN 13363-2의 분석에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author김동균-
dc.contributor.author전종욱-
dc.contributor.author김강수-
dc.date.accessioned2021-09-07T18:02:03Z-
dc.date.available2021-09-07T18:02:03Z-
dc.date.created2021-06-17-
dc.date.issued2011-
dc.identifier.issn2733-6239-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/113839-
dc.description.abstractRecently, the matter of excessive cooling load in buildings is being occurred in summer. This problem is mainly due to uncontrolled solar radiation transmitted to building envelope. To control transmitted solar radiation, shading devices are generally used in buildings. Among shading devices, venetian blind has the advantage to adjust indoor comfort and visual comfort by slat angle control. This paper is focused on comparisons of calculation methods for solar transmittance, which is used in EnergyPlus and DIN EN 13363-2 for thermal simulation of venetian blind combined with glazing. Generally, total solar transmittance is calculated through correlations of glazing transmittance and venetian blind transmittance. EnergyPlus considers angular dependance for calculating glazing transmittance, and it uses Radiosity Method for blind transmittance calculation. However, DIN EN 13363-2assumed normal incident angle for glazing transmittance and it uses different method for calculating blind transmittance, which is more simplified than EnergyPlus. Consequently, EnergyPlus algorithms demand more detailed information than DIN EN 13363-2 to calculate solar transmittance of glazing system. Furthermore, EnergyPlus always had higher blind transmittance than that of DIN EN 13363-2, due to consider of inner reflection for venetian blind, However, DIN EN 13363-2 always had higher glazing transmittance than EnergyPlus,because it assumed normal incident angle. As a result, they show similar results for total solar transmittance of glazing system.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한건축학회-
dc.title베네시안 블라인드가 적용된 창호 시스템의 1차 투과율 평가를 위한 에너지 플러스 알고리즘과 DIN EN 13363-2의 분석에 관한 연구-
dc.title.alternativeComparison of EnergyPlus Algorithm with DIN EN 13363-2 to Evaluate Solar Transmittance for Glazing System with Venetian Blind-
dc.typeArticle-
dc.contributor.affiliatedAuthor전종욱-
dc.contributor.affiliatedAuthor김강수-
dc.identifier.bibliographicCitation대한건축학회논문집, v.27, no.11, pp.373 - 380-
dc.relation.isPartOf대한건축학회논문집-
dc.citation.title대한건축학회논문집-
dc.citation.volume27-
dc.citation.number11-
dc.citation.startPage373-
dc.citation.endPage380-
dc.type.rimsART-
dc.identifier.kciidART001605163-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor에너지 플러스-
dc.subject.keywordAuthorDIN EN 13363-2-
dc.subject.keywordAuthor일사 투과율-
dc.subject.keywordAuthor창호시스템-
dc.subject.keywordAuthor레디오시티 계산법-
dc.subject.keywordAuthor베네시안 블라인드-
dc.subject.keywordAuthorEnergyPlus-
dc.subject.keywordAuthorDIN EN 13363-2-
dc.subject.keywordAuthorSolar Transmittance-
dc.subject.keywordAuthorGlazing System-
dc.subject.keywordAuthorRaiosity Method-
dc.subject.keywordAuthorVenetian Blind-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE