Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

동맥 스핀 라벨링 자기공명영상의 펄스 관류 신호의 시뮬레이션

Full metadata record
DC Field Value Language
dc.contributor.author김혁기-
dc.contributor.author장건호-
dc.contributor.author오창현-
dc.date.accessioned2021-09-07T18:02:32Z-
dc.date.available2021-09-07T18:02:32Z-
dc.date.created2021-06-17-
dc.date.issued2011-
dc.identifier.issn2384-1095-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/113842-
dc.description.abstractPurpose: A pulsed arterial spin labeling (PASL) signal usually depends on several parameters. The objective of this study was to determine the optimal parameters using simulation for perfusion signals of PASL magnetic resonance imaging (MRI). Materials and methods: Perfusion signals, ΔM/M_(0b), derived from the Bloch equation were evaluated in regard to the four most important parameters in PASL MRI: the tissue-to-blood coefficient (λ), the longitudinal relaxation time of blood (T_(1b)), the arterial transit delay from the application of tag (δt), and the magnetic field strength (B0). The simulation was conducted with Mathematica software. Results: First, perfusion signals differed depending on the value of λ in brain tissue. The maximum signal, ΔM/M_(0b) = 0.390, was obtained at an inversion time (TI) = 1.53 sec for gray matter on 3T MRI. Second, perfusion signals were reduced with increasing δt. The maximum signal, ΔM/M0b = 0.526, was obtained at TI = 2.1 sec for δt = 0.5 sec. Finally, perfusion signals increased with increasing B0. The maximum signal, ΔM = 1.15, was obtained at TI = 1.52 sec for 3T MRI. Conclusion: We reported that the optimized TI values were obtained to provide the highest PASL signals. It is very important that optimized TI values be used to obtain high-quality perfusion signals using PASL MRI.-
dc.languageEnglish-
dc.language.isoen-
dc.publisher대한자기공명의과학회-
dc.title동맥 스핀 라벨링 자기공명영상의 펄스 관류 신호의 시뮬레이션-
dc.title.alternativeSimulations of Perfusion Signals of Pulsed Arterial Spin Labeling MRI-
dc.typeArticle-
dc.contributor.affiliatedAuthor오창현-
dc.identifier.bibliographicCitationInvestigative Magnetic Resonance Imaging, v.15, no.3, pp.191 - 199-
dc.relation.isPartOfInvestigative Magnetic Resonance Imaging-
dc.citation.titleInvestigative Magnetic Resonance Imaging-
dc.citation.volume15-
dc.citation.number3-
dc.citation.startPage191-
dc.citation.endPage199-
dc.type.rimsART-
dc.identifier.kciidART001622794-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorPerfusion-
dc.subject.keywordAuthorarterial spin labeling-
dc.subject.keywordAuthorBloch equation-
dc.subject.keywordAuthorcerebral blood flow-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Electronics and Information Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE