동맥 스핀 라벨링 자기공명영상의 펄스 관류 신호의 시뮬레이션
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김혁기 | - |
dc.contributor.author | 장건호 | - |
dc.contributor.author | 오창현 | - |
dc.date.accessioned | 2021-09-07T18:02:32Z | - |
dc.date.available | 2021-09-07T18:02:32Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2011 | - |
dc.identifier.issn | 2384-1095 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/113842 | - |
dc.description.abstract | Purpose: A pulsed arterial spin labeling (PASL) signal usually depends on several parameters. The objective of this study was to determine the optimal parameters using simulation for perfusion signals of PASL magnetic resonance imaging (MRI). Materials and methods: Perfusion signals, ΔM/M_(0b), derived from the Bloch equation were evaluated in regard to the four most important parameters in PASL MRI: the tissue-to-blood coefficient (λ), the longitudinal relaxation time of blood (T_(1b)), the arterial transit delay from the application of tag (δt), and the magnetic field strength (B0). The simulation was conducted with Mathematica software. Results: First, perfusion signals differed depending on the value of λ in brain tissue. The maximum signal, ΔM/M_(0b) = 0.390, was obtained at an inversion time (TI) = 1.53 sec for gray matter on 3T MRI. Second, perfusion signals were reduced with increasing δt. The maximum signal, ΔM/M0b = 0.526, was obtained at TI = 2.1 sec for δt = 0.5 sec. Finally, perfusion signals increased with increasing B0. The maximum signal, ΔM = 1.15, was obtained at TI = 1.52 sec for 3T MRI. Conclusion: We reported that the optimized TI values were obtained to provide the highest PASL signals. It is very important that optimized TI values be used to obtain high-quality perfusion signals using PASL MRI. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | 대한자기공명의과학회 | - |
dc.title | 동맥 스핀 라벨링 자기공명영상의 펄스 관류 신호의 시뮬레이션 | - |
dc.title.alternative | Simulations of Perfusion Signals of Pulsed Arterial Spin Labeling MRI | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 오창현 | - |
dc.identifier.bibliographicCitation | Investigative Magnetic Resonance Imaging, v.15, no.3, pp.191 - 199 | - |
dc.relation.isPartOf | Investigative Magnetic Resonance Imaging | - |
dc.citation.title | Investigative Magnetic Resonance Imaging | - |
dc.citation.volume | 15 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 191 | - |
dc.citation.endPage | 199 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001622794 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Perfusion | - |
dc.subject.keywordAuthor | arterial spin labeling | - |
dc.subject.keywordAuthor | Bloch equation | - |
dc.subject.keywordAuthor | cerebral blood flow | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.