Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR의 말라리아 진단 유용성Evaluation of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria

Other Titles
Evaluation of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR for the Diagnosis of Malaria
Authors
이혜진김하늬유병준김장수김명한임채승이갑노
Issue Date
2011
Publisher
대한진단검사의학회
Keywords
Malaria; Real time quantitative PCR; Diagnosis
Citation
Laboratory Medicine Online, v.1, no.2, pp.100 - 104
Indexed
KCI
OTHER
Journal Title
Laboratory Medicine Online
Volume
1
Number
2
Start Page
100
End Page
104
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/114411
ISSN
2093-6338
Abstract
Background: Malaria is a problematic disease in Korea, and microscopic examination of Giemsa-stained blood smear has been used as the gold standard for its diagnosis. However, this technique is time-consuming and has low sensitivity in samples with low numbers of malarial parasites (<20 parasites/μL). Here, we evaluated the performance characteristics of the LG Advansure^(TM) Malaria P.f./P.v. real-time QPCR (LG life sciences,Korea). Methods: Blood samples from 173 persons who visited Korea University Ansan Hospital were evaluated. QPCR was performed in 73 malaria patients and 100 healthy subjects by using the LG Advansure Malaria P.f./P.v. real-time QPCRR kit, and the results were compared with those of microscopy. The detection limit of this kit was determined by serial dilution of Plasmodium-infected blood with normal blood (blood not infected with Plasmodium). Results: Among the 73 patients that were microscopically confirmed to have malaria (Plasmodium vivax infection, N=70, P. falciparum infection,N=3), 69 patients were diagnosed with P. vivax infection and 3 were diagnosed with P. falciparum infection by LG Advansure^(TM) Malaria P.f./P.v. realtime QPCR. Both the tests indicated absence of infection in the 100 healthy subjects. The detection limit of LG Advansure^(TM)Malaria P.f./P.v. real-time QPCR was 0.1 parasite/μL. Conclusions: LG Advansure^(TM Malaria P.f./P.v. real-time QPCRis a very sensitive and specific technique and can be used as a confirmatory test for malaria.
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE