Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC AC의 사례 중심으로 -

Full metadata record
DC Field Value Language
dc.contributor.author김재홍-
dc.contributor.author김혜영-
dc.contributor.author김지환-
dc.date.accessioned2021-09-07T19:52:18Z-
dc.date.available2021-09-07T19:52:18Z-
dc.date.created2021-06-17-
dc.date.issued2011-
dc.identifier.issn1229-3954-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/114431-
dc.description.abstractPurpose: The purpose of the study was a quantitative evaluation of common errors in digital impression procedure using CEREC AC system. Methods: Two-hundreds digital impression data comprising 174 inlays, 26 onlays by CEREC AC in-office CAD/CAM system were obtained from a dental clinic. One evaluator assessed errors of the digital impression data and divided into five categories of errors: inappropriate scanner positioning (ISP), improper handling with a scanner (IHS), irregular powder arrangement (IPA), improper cavity preparation (ICP), and insufficient scanned data (ISD). Results: The most common errors were IPA(21%), and ISP and ISD were followed by 17% respectively. IHS was found in 14.5% of all digital impression data. ICP comprising only 6.5% was the rarest. Conclusion: Most errors were due to inaccurate manipulation with an intraoral scanner or improper cavity preparation for scanning. A deliberate manipulation to prevent common errors mentioned may deliver an optimal result in the digital impression procedure.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한치과기공학회-
dc.title디지털 인상 채득 시 흔히 발생하는 오류에 관한 연구 - CEREC AC의 사례 중심으로 --
dc.title.alternativeA study on Common Errors in Digital Impressions: (An Example of CEREC AC)-
dc.typeArticle-
dc.contributor.affiliatedAuthor김혜영-
dc.contributor.affiliatedAuthor김지환-
dc.identifier.bibliographicCitation대한치과기공학회지, v.33, no.3, pp.211 - 218-
dc.relation.isPartOf대한치과기공학회지-
dc.citation.title대한치과기공학회지-
dc.citation.volume33-
dc.citation.number3-
dc.citation.startPage211-
dc.citation.endPage218-
dc.type.rimsART-
dc.identifier.kciidART001596311-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorCEREC AC-
dc.subject.keywordAuthordental restoration-
dc.subject.keywordAuthordigital impression-
dc.subject.keywordAuthorintraoral scanner-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hae Young photo

Kim, Hae Young
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE