Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A STUDY OF RELATIVE PERFORMANCE BETWEEN DIRECT INJECTION AND THERMAL DESORPTION FOR SEVERAL VOLATILE ORGANIC ACIDS AND REFERENCE VOCS BY GAS CHROMATOGRAPHY - MASS SPECTROMETRY

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Ki-Hyun-
dc.contributor.authorSusaya, Janice-
dc.contributor.authorSohn, Jong Ryeul-
dc.contributor.authorBrown, Richard J. C.-
dc.date.accessioned2021-09-07T21:44:33Z-
dc.date.available2021-09-07T21:44:33Z-
dc.date.created2021-06-14-
dc.date.issued2011-
dc.identifier.issn1018-4619-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/114979-
dc.description.abstractIn this research, the relative performance of gas chromatography - mass spectrometry (GC-MS) has been examined to compare the recovery rates (RR) obtained for several volatile organic acids in air when using different sample introduction methods. To this end, a comparison was performed between direct injection (DI) and thermal desorption (TD) for introduction of the samples into the GC-MS. The GC-MS system was calibrated initially by using liquid phase working standards (L-WS) comprising a mixture of 13 volatile organic compounds (VOCs) with a main emphasis on volatile organic acids and several reference compounds including aromatics with and without the use of TD. Assuming that one can acquire the optimum sensitivity for any given individual compound by direct injection (DI: i.e., without TD), the response factors (RF) derived by the DI method are compared against those of TD on a compound-by-compound basis to assess the relative sensitivity attributable to the two methods. To this end, the RF values are adjusted for each VOC and each of the two different approaches by considering the different split ratios for TD and DI. According to this comparison, the RR of the TD method tends to vary with target compound; however, a RR near unity is attained for most VOCs except for MEK and organic acids.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPARLAR SCIENTIFIC PUBLICATIONS (P S P)-
dc.subjectREDUCED SULFUR-COMPOUNDS-
dc.subjectAIR-
dc.subjectRANGE-
dc.subjectWATER-
dc.titleA STUDY OF RELATIVE PERFORMANCE BETWEEN DIRECT INJECTION AND THERMAL DESORPTION FOR SEVERAL VOLATILE ORGANIC ACIDS AND REFERENCE VOCS BY GAS CHROMATOGRAPHY - MASS SPECTROMETRY-
dc.typeArticle-
dc.contributor.affiliatedAuthorSohn, Jong Ryeul-
dc.identifier.scopusid2-s2.0-84555177360-
dc.identifier.wosid000298067100009-
dc.identifier.bibliographicCitationFRESENIUS ENVIRONMENTAL BULLETIN, v.20, no.11, pp.2875 - 2882-
dc.relation.isPartOfFRESENIUS ENVIRONMENTAL BULLETIN-
dc.citation.titleFRESENIUS ENVIRONMENTAL BULLETIN-
dc.citation.volume20-
dc.citation.number11-
dc.citation.startPage2875-
dc.citation.endPage2882-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.subject.keywordPlusREDUCED SULFUR-COMPOUNDS-
dc.subject.keywordPlusAIR-
dc.subject.keywordPlusRANGE-
dc.subject.keywordPlusWATER-
dc.subject.keywordAuthorGas chromatography (GC)-
dc.subject.keywordAuthorMass spectrometry (MS)-
dc.subject.keywordAuthorVolatile organic compounds (VOCs)-
dc.subject.keywordAuthorCalibration-
dc.subject.keywordAuthorResponse factor (RF)-
dc.subject.keywordAuthorRecovery rate (RR)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE