Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The perspectives of users and developers in designing and developing O-arm imaging system

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Moon Seok-
dc.contributor.authorChung, Chin Youb-
dc.contributor.authorKwon, Dae Gyu-
dc.contributor.authorHuh, Young-
dc.contributor.authorLee, Kisung-
dc.contributor.authorLee, Kyoung Min-
dc.date.accessioned2021-09-07T21:59:49Z-
dc.date.available2021-09-07T21:59:49Z-
dc.date.created2021-06-14-
dc.date.issued2011-
dc.identifier.issn0895-3996-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/115065-
dc.description.abstractA questionnaire survey was performed to investigate the different knowledge of radiation exposure, awareness and expectation for O-arm imaging system between the users (orthopaedic surgeons) and the developers (engineers). A total of 93 orthopaedic surgeons and 19 engineers participated and answered the questionnaire consisting of 18 items designed for this study. The items were focused on knowlege, awareness, and expectation. Orthopaedic surgeons had higher scores for items of knowledge domains regarding radiation exposure than the engineers while the engineers were more sensitive to radiation hazards and adopted higher levels of radiation protection than orthopaedic surgeons in the awareness domain. Most engineers and orthopaedic surgeons answered that the requirements of diagnostic and intraoperative imaging systems differ. Image resolution, a low radiation exposure, and the time required for image acquisition was the top three requirements of O-arm selected by engineers. On the other hand, the top three requirements according to orthopaedic surgeons were; image resolution, expediency, and spatial occupancy. User requirements need to be reflected in developing O-arm along with basic requirements such as image resolution and low radiation exposure.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOS PRESS-
dc.subjectRADIATION-EXPOSURE-
dc.subjectAWARENESS-
dc.titleThe perspectives of users and developers in designing and developing O-arm imaging system-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Kisung-
dc.identifier.doi10.3233/XST-2011-0286-
dc.identifier.scopusid2-s2.0-79959281647-
dc.identifier.wosid000292735700004-
dc.identifier.bibliographicCitationJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, v.19, no.2, pp.199 - 204-
dc.relation.isPartOfJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.titleJOURNAL OF X-RAY SCIENCE AND TECHNOLOGY-
dc.citation.volume19-
dc.citation.number2-
dc.citation.startPage199-
dc.citation.endPage204-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.subject.keywordPlusRADIATION-EXPOSURE-
dc.subject.keywordPlusAWARENESS-
dc.subject.keywordAuthorO-arm-
dc.subject.keywordAuthorquestionnaire-
dc.subject.keywordAuthordifferent perspective-
dc.subject.keywordAuthoruser-
dc.subject.keywordAuthordeveloper-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Ki sung photo

Lee, Ki sung
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE