Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Min-Jung | - |
dc.contributor.author | Hwang, Sung Woo | - |
dc.contributor.author | Whang, Dongmok | - |
dc.date.accessioned | 2021-09-07T22:17:01Z | - |
dc.date.available | 2021-09-07T22:17:01Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2010-12 | - |
dc.identifier.issn | 0021-891X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/115146 | - |
dc.description.abstract | A novel amperometric biosensor for the detection of hydrogen peroxide (H2O2) was prepared by immobilizing horseradish peroxidase (HRP) on highly dense silver nanowire (Ag-NW) film. The modified electrode was characterized using UV-Vis spectroscopy, scanning electron microscopy, X-ray diffraction, and transmission electron microscopy. The electrochemical performances of the electrode were studied by cyclic voltammetry and chronoamperometry. The HRPs immobilized on the surface of Ag-NWs exhibited an excellent electrocatalytic response toward reduction of H2O2. The resulting Ag-NW modified sensor showed a sensitivity of similar to 2.55 mu A mu M-1 (correlation coefficient r = 0.9969) with a linear range of 4.8 nM-0.31 mu M. Its detection limit was 1.2 nM with a signal-to-noise ratio of 3. The Michaelis-Menten constant K (M) (app) and the maximum current density I (max) of the modified electrode were 0.0071 mM and 8.475 mu A, respectively. The preparation process of the proposed biosensor was convenient, and the resulting biosensor showed high sensitivity, low detection limit and good stability. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.subject | HORSERADISH-PEROXIDASE | - |
dc.subject | SENSORS | - |
dc.subject | IMMOBILIZATION | - |
dc.subject | HEMOGLOBIN | - |
dc.subject | NANORODS | - |
dc.subject | GLUCOSE | - |
dc.title | Amperometric hydrogen peroxide biosensor based on a modified gold electrode with silver nanowires | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Song, Min-Jung | - |
dc.contributor.affiliatedAuthor | Hwang, Sung Woo | - |
dc.identifier.doi | 10.1007/s10800-010-0191-x | - |
dc.identifier.scopusid | 2-s2.0-78650875615 | - |
dc.identifier.wosid | 000284601200004 | - |
dc.identifier.bibliographicCitation | JOURNAL OF APPLIED ELECTROCHEMISTRY, v.40, no.12, pp.2099 - 2105 | - |
dc.relation.isPartOf | JOURNAL OF APPLIED ELECTROCHEMISTRY | - |
dc.citation.title | JOURNAL OF APPLIED ELECTROCHEMISTRY | - |
dc.citation.volume | 40 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 2099 | - |
dc.citation.endPage | 2105 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.subject.keywordPlus | HORSERADISH-PEROXIDASE | - |
dc.subject.keywordPlus | SENSORS | - |
dc.subject.keywordPlus | IMMOBILIZATION | - |
dc.subject.keywordPlus | HEMOGLOBIN | - |
dc.subject.keywordPlus | NANORODS | - |
dc.subject.keywordPlus | GLUCOSE | - |
dc.subject.keywordAuthor | Electrochemical sensor | - |
dc.subject.keywordAuthor | Hydrogen peroxide | - |
dc.subject.keywordAuthor | Horseradish peroxidase | - |
dc.subject.keywordAuthor | Silver nanowires | - |
dc.subject.keywordAuthor | Self-assembled monolayers | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.