Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of Various Formulae for Glomerular Filtration Rate Estimation and Proposal of New Formulae for the Korean Population

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Chi Hyun-
dc.contributor.authorRoh, Kyoung Ho-
dc.contributor.authorNam, Myung Hyun-
dc.contributor.authorKim, Jang Su-
dc.contributor.authorLim, Chae-Seung-
dc.contributor.authorLee, Chang Kyu-
dc.contributor.authorLee, Kap-No-
dc.contributor.authorKim, Young Kee-
dc.date.accessioned2021-09-07T22:26:09Z-
dc.date.available2021-09-07T22:26:09Z-
dc.date.created2021-06-14-
dc.date.issued2010-12-
dc.identifier.issn1598-6535-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/115196-
dc.description.abstractBackground : Some researchers have questioned the necessity of adjusting glomerular filtration rate (GFR) by body surface area (BSA). We compared the relationship between estimated GFR (eGFR) and radionuclide GFR (rGFR) with or without BSA adjustment by comparing the results obtained using various formulae with those obtained using 2 new proposed formulae. Methods : A retrospective study was performed using 204 Korean individuals whose GFR had been estimated by the Tc-99m-diethylenetriaminepentaacetic acid method between March 2004 and July 2008. We used the modification of diet in renal disease (MDRD) II formula, Mayo clinic quadratic (MOO) formula, Cockcroft-Gault (CG) formula, and lean body mass-adjusted CG formula. Two new formulae, skeletal muscle mass index (SMI)-adjusted CG formula and SMI x 3.4/SCr, were proposed by us. We analyzed each parameter with Pearson's correlation coefficient and also obtained the bias values. Results : BSA did not satisfy the fundamental prerequisites of an adjustment factor for rGFR. MDRD II and MOO GFR estimates demonstrated higher Pearson's correlation coefficient with BSA-unadjusted rGFR than they did with BSA-adjusted rGFR. The other GFR formulae estimates showed better correlation with rGFR and more favorable bias (P<0.001) when both GFR estimates and rGFR values were BSA-unadjusted. SMI-adjusted CG and SMI x 3.4/SCr GFR estimates demonstrated correlation with rGFR and bias values similar to those of the MDRD II and CG GFR estimates. Conclusions : We suggest that absolute, non-corrected GFR and GFR estimate be preferred in daily practice. The absolute, non-corrected GFR and GFR estimate are considered helpful for patients with eGFR <= 60 mL/min/1.73 m(2). We also recommend the clinical use of the new formulae, SMI-adjusted CG and SMI X 3.415Cr (BSA-unadjusted). (Korean J Lab Med 201030:606-15)-
dc.languageKorean-
dc.language.isoko-
dc.publisherKOREAN SOC LABORATORY MEDICINE-
dc.subjectBODY-SURFACE AREA-
dc.subjectCOCKCROFT-GAULT EQUATIONS-
dc.subjectESTIMATING RENAL-FUNCTION-
dc.subjectC-BASED GFR-
dc.subjectSERUM CREATININE-
dc.subjectKIDNEY-DISEASE-
dc.subjectCYSTATIN-C-
dc.subjectPREDICTIVE PERFORMANCE-
dc.subjectIMPROVES-
dc.subjectWEIGHT-
dc.titleEvaluation of Various Formulae for Glomerular Filtration Rate Estimation and Proposal of New Formulae for the Korean Population-
dc.typeArticle-
dc.contributor.affiliatedAuthorCho, Chi Hyun-
dc.identifier.doi10.3343/kjlm.2010.30.6.606-
dc.identifier.scopusid2-s2.0-78651296256-
dc.identifier.wosid000285530300014-
dc.identifier.bibliographicCitationKOREAN JOURNAL OF LABORATORY MEDICINE, v.30, no.6, pp.606 - 615-
dc.relation.isPartOfKOREAN JOURNAL OF LABORATORY MEDICINE-
dc.citation.titleKOREAN JOURNAL OF LABORATORY MEDICINE-
dc.citation.volume30-
dc.citation.number6-
dc.citation.startPage606-
dc.citation.endPage615-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001497827-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaMedical Laboratory Technology-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.subject.keywordPlusBODY-SURFACE AREA-
dc.subject.keywordPlusCOCKCROFT-GAULT EQUATIONS-
dc.subject.keywordPlusESTIMATING RENAL-FUNCTION-
dc.subject.keywordPlusC-BASED GFR-
dc.subject.keywordPlusSERUM CREATININE-
dc.subject.keywordPlusKIDNEY-DISEASE-
dc.subject.keywordPlusCYSTATIN-C-
dc.subject.keywordPlusPREDICTIVE PERFORMANCE-
dc.subject.keywordPlusIMPROVES-
dc.subject.keywordPlusWEIGHT-
dc.subject.keywordAuthorGlomerular filtration rate-
dc.subject.keywordAuthorFormula-
dc.subject.keywordAuthorBody surface area-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE