Estimation of proton distribution by means of three-dimensional reconstruction of prompt gamma rays
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Min-Seok | - |
dc.contributor.author | Lee, Wonho | - |
dc.contributor.author | Kim, Jung-Min | - |
dc.date.accessioned | 2021-09-07T23:34:19Z | - |
dc.date.available | 2021-09-07T23:34:19Z | - |
dc.date.created | 2021-06-14 | - |
dc.date.issued | 2010-10-11 | - |
dc.identifier.issn | 0003-6951 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/115519 | - |
dc.description.abstract | In proton therapy, the dose distribution of proton beams in the human body needs to be measured accurately. The distribution of prompt gamma rays emitted from patients during irradiation is strongly associated with the dose distribution of the proton beam. The (three-dimensional) 3D distribution of the prompt gamma rays detected by a single photon emission computed tomography was simulated using a Monte Carlo method. The 3D distribution of the prompt gamma rays was well matched with the dose distribution of the proton beam and was superior to the (two-dimensional) distribution of the prompt gamma rays detected using a conventional gamma camera. (C) 2010 American Institute of Physics. [doi: 10.1063/1.3502612] | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER INST PHYSICS | - |
dc.subject | THERAPY | - |
dc.subject | PET | - |
dc.subject | BEAM | - |
dc.title | Estimation of proton distribution by means of three-dimensional reconstruction of prompt gamma rays | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Wonho | - |
dc.contributor.affiliatedAuthor | Kim, Jung-Min | - |
dc.identifier.doi | 10.1063/1.3502612 | - |
dc.identifier.scopusid | 2-s2.0-77958101351 | - |
dc.identifier.wosid | 000283216900094 | - |
dc.identifier.bibliographicCitation | APPLIED PHYSICS LETTERS, v.97, no.15 | - |
dc.relation.isPartOf | APPLIED PHYSICS LETTERS | - |
dc.citation.title | APPLIED PHYSICS LETTERS | - |
dc.citation.volume | 97 | - |
dc.citation.number | 15 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | THERAPY | - |
dc.subject.keywordPlus | PET | - |
dc.subject.keywordPlus | BEAM | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.