Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

False Negative and Positive Motor Evoked Potentials in One Patient: Is Single Motor Evoked Potential Monitoring Reliable Method? A Case Report and Literature Review

Full metadata record
DC Field Value Language
dc.contributor.authorHong, Jae-Young-
dc.contributor.authorSuh, Seung-Woo-
dc.contributor.authorModi, Hitesh N.-
dc.contributor.authorHur, Chang-Yong-
dc.contributor.authorSong, Hae-Ryong-
dc.contributor.authorPark, Jong Hoon-
dc.date.accessioned2021-09-08T00:58:48Z-
dc.date.available2021-09-08T00:58:48Z-
dc.date.created2021-06-14-
dc.date.issued2010-08-15-
dc.identifier.issn0362-2436-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/115881-
dc.description.abstractStudy Design. A case report and literature review. Objective. To report a false negative and delayed positive motor-evoked potential (MEP) in 1 patient. Summary of Background Data. An unreliable MEP can result in fatal outcomes because surgeons have recently begun to depend on the MEP for intraoperative decision-making. Methods. We report a case of a false MEP during scoliosis surgery that showed false negative and positive MEPs during a series of operations. Results. A 23-year-old man with a history of spondyloepiphyseal dysplasia presented with severe kyphoscoliosis. The initial neurologic examination did not reveal any neurologic abnormalities. Surgical correction and fusion were performed with transcranial MEP monitoring. During the entire procedure, the MEP did not reveal any signs of cord injury. However, lower limb paralysis and paresthesia was observed when the patient awakened. After 2 additional surgical procedures to recover the neurologic deficit, the MEP did not show any signs of cord injury but the patient's neurologic status had recovered slightly. At postoperative day 8, the neurologic status recovered, and a third operation was performed to fix the long rods. However, there were abnormal amplitudes in both lower limbs but the patient's neurologic status was almost normal. Conclusion. From our experience of false negative and positive MEP in 1 patient, it is concluded that undesirable events can occur with use of MEP in scoliosis or other spinal surgery. Therefore, we warn the surgeons too heavily rely on the MEP monitoring, and propose a further prospective study as well as use of alternative method that can improve the reliability of single MEP.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.subjectSPINAL-CORD-INJURY-
dc.subjectSCOLIOSIS SURGERY-
dc.subjectGENERAL-ANESTHESIA-
dc.subjectCATHODAL STIMULATION-
dc.subjectSURGICAL-TREATMENT-
dc.subjectCEREBRAL-PALSY-
dc.subjectCORTEX-
dc.subjectHUMANS-
dc.titleFalse Negative and Positive Motor Evoked Potentials in One Patient: Is Single Motor Evoked Potential Monitoring Reliable Method? A Case Report and Literature Review-
dc.typeArticle-
dc.contributor.affiliatedAuthorHong, Jae-Young-
dc.contributor.affiliatedAuthorSuh, Seung-Woo-
dc.contributor.affiliatedAuthorHur, Chang-Yong-
dc.contributor.affiliatedAuthorSong, Hae-Ryong-
dc.contributor.affiliatedAuthorPark, Jong Hoon-
dc.identifier.doi10.1097/BRS.0b013e3181d8fabb-
dc.identifier.scopusid2-s2.0-77955929629-
dc.identifier.wosid000281277700021-
dc.identifier.bibliographicCitationSPINE, v.35, no.18, pp.E912 - E916-
dc.relation.isPartOfSPINE-
dc.citation.titleSPINE-
dc.citation.volume35-
dc.citation.number18-
dc.citation.startPageE912-
dc.citation.endPageE916-
dc.type.rimsART-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaOrthopedics-
dc.relation.journalWebOfScienceCategoryClinical Neurology-
dc.relation.journalWebOfScienceCategoryOrthopedics-
dc.subject.keywordPlusSPINAL-CORD-INJURY-
dc.subject.keywordPlusSCOLIOSIS SURGERY-
dc.subject.keywordPlusGENERAL-ANESTHESIA-
dc.subject.keywordPlusCATHODAL STIMULATION-
dc.subject.keywordPlusSURGICAL-TREATMENT-
dc.subject.keywordPlusCEREBRAL-PALSY-
dc.subject.keywordPlusCORTEX-
dc.subject.keywordPlusHUMANS-
dc.subject.keywordAuthorfalse negative-
dc.subject.keywordAuthorfalse positive-
dc.subject.keywordAuthormotor evoked potentials-
dc.subject.keywordAuthorintraoperative neurophysiological monitoring-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Suh, Seung Woo photo

Suh, Seung Woo
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE