Technical pitfall while reducing the mismatch between LCP PLT and upper end Tibia in proximal Tibia fractures
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Jong-Keon | - |
dc.contributor.author | Sahu, Dipit | - |
dc.contributor.author | Hwang, Jin-Ho | - |
dc.contributor.author | Cho, Jae-Woo | - |
dc.contributor.author | Oh, Chang-Wug | - |
dc.date.accessioned | 2021-09-08T02:42:20Z | - |
dc.date.available | 2021-09-08T02:42:20Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2010-06 | - |
dc.identifier.issn | 0936-8051 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/116325 | - |
dc.description.abstract | Minimal invasive technique along with the widespread use of the new pre contoured locking plates (LCP PLT, LISS PLT) has given rise many alignment related problems in fractures of proximal tibia. A significant implant related problem with the use of pre contoured locking plate in proximal tibia fractures is the hardware irritation of the subcutaneous tissue by upper end of plate. This is caused by the large profile of the implant which sits off the bone at the proximal end. A general recommendation made by some is to try and reduce the bone and plate together with the help of pelvic reduction clamps. We have identified this as a source of error in our practice which has a potential to introduce malalignment in tibia, most often discovered post operatively. Here we will describe with relevant cases, the pitfall in the recommended technique and steps to be taken to avoid this error. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.subject | INVASIVE STABILIZATION SYSTEM | - |
dc.subject | DISTAL FEMORAL FRACTURES | - |
dc.subject | LISS | - |
dc.subject | FIXATION | - |
dc.subject | PLATEAU | - |
dc.title | Technical pitfall while reducing the mismatch between LCP PLT and upper end Tibia in proximal Tibia fractures | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Oh, Jong-Keon | - |
dc.identifier.doi | 10.1007/s00402-009-0949-y | - |
dc.identifier.scopusid | 2-s2.0-77953292426 | - |
dc.identifier.wosid | 000277626500007 | - |
dc.identifier.bibliographicCitation | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v.130, no.6, pp.759 - 763 | - |
dc.relation.isPartOf | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY | - |
dc.citation.title | ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY | - |
dc.citation.volume | 130 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 759 | - |
dc.citation.endPage | 763 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | INVASIVE STABILIZATION SYSTEM | - |
dc.subject.keywordPlus | DISTAL FEMORAL FRACTURES | - |
dc.subject.keywordPlus | LISS | - |
dc.subject.keywordPlus | FIXATION | - |
dc.subject.keywordPlus | PLATEAU | - |
dc.subject.keywordAuthor | LCP PLT | - |
dc.subject.keywordAuthor | Malalignment | - |
dc.subject.keywordAuthor | Mismatch | - |
dc.subject.keywordAuthor | Proximal tibia fractures | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.