Source identification of particulate matter collected at underground subway stations in Seoul, Korea using quantitative single-particle analysis
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jung, Hae-Jin | - |
dc.contributor.author | Kim, BoWha | - |
dc.contributor.author | Ryu, JiYeon | - |
dc.contributor.author | Maskey, Shila | - |
dc.contributor.author | Kim, Jo-Chun | - |
dc.contributor.author | Sohn, Jongryeul | - |
dc.contributor.author | Ro, Chul-Un | - |
dc.date.accessioned | 2021-09-08T02:46:45Z | - |
dc.date.available | 2021-09-08T02:46:45Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2010-06 | - |
dc.identifier.issn | 1352-2310 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/116349 | - |
dc.description.abstract | Subway particle samples collected at four underground subway stations in Seoul, Korea were characterized by a single-particle analytical technique, low-Z particle electron probe X-ray microanalysis. To clearly identify indoor sources of subway particles, four sets of samples collected in tunnels, at platforms, near ticket offices, and outdoors were investigated. For the samples collected in tunnels, Fe-containing particles predominate, with relative abundances of 75-91% for the four stations. The amounts of Fe-containing particles decrease as the distance of sampling locations from the tunnel increases. In addition, samples collected at the platform in subway stations with platform screen doors (PSDs) that limit airmixing between the platform and the tunnel showed marked decreases in relative abundances of Fe-containing particles, clearly indicating that Fe-containing subway particles are generated in the tunnel. PM10 mass concentration levels are the highest in the tunnels, becoming lower as the distance of sampling locations from the tunnel increases. The extent of the decrease in PM10 in stations with PSDs is also larger than that in stations without PSDs. The results clearly indicate that Fe-containing particles originating in tunnels predominate in the indoor microenvironment of subway stations, resulting in high indoor PM10 levels, and that PSDs play a significant role in reducing Fe-containing particles at platforms and near ticket offices. (C) 2010 Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.subject | X-RAY-MICROANALYSIS | - |
dc.subject | PERSONAL EXPOSURE LEVELS | - |
dc.subject | TRANSPORT MICROENVIRONMENTS | - |
dc.subject | ELEMENTAL COMPOSITION | - |
dc.subject | INDIVIDUAL PARTICLES | - |
dc.subject | AIRBORNE PARTICLES | - |
dc.subject | AEROSOL-PARTICLES | - |
dc.subject | RAILWAY STATION | - |
dc.subject | MINERAL DUST | - |
dc.subject | SYSTEM | - |
dc.title | Source identification of particulate matter collected at underground subway stations in Seoul, Korea using quantitative single-particle analysis | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Sohn, Jongryeul | - |
dc.identifier.doi | 10.1016/j.atmosenv.2010.04.003 | - |
dc.identifier.scopusid | 2-s2.0-77953110044 | - |
dc.identifier.wosid | 000279043400004 | - |
dc.identifier.bibliographicCitation | ATMOSPHERIC ENVIRONMENT, v.44, no.19, pp.2287 - 2293 | - |
dc.relation.isPartOf | ATMOSPHERIC ENVIRONMENT | - |
dc.citation.title | ATMOSPHERIC ENVIRONMENT | - |
dc.citation.volume | 44 | - |
dc.citation.number | 19 | - |
dc.citation.startPage | 2287 | - |
dc.citation.endPage | 2293 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Meteorology & Atmospheric Sciences | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Meteorology & Atmospheric Sciences | - |
dc.subject.keywordPlus | X-RAY-MICROANALYSIS | - |
dc.subject.keywordPlus | PERSONAL EXPOSURE LEVELS | - |
dc.subject.keywordPlus | TRANSPORT MICROENVIRONMENTS | - |
dc.subject.keywordPlus | ELEMENTAL COMPOSITION | - |
dc.subject.keywordPlus | INDIVIDUAL PARTICLES | - |
dc.subject.keywordPlus | AIRBORNE PARTICLES | - |
dc.subject.keywordPlus | AEROSOL-PARTICLES | - |
dc.subject.keywordPlus | RAILWAY STATION | - |
dc.subject.keywordPlus | MINERAL DUST | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordAuthor | Subway particles | - |
dc.subject.keywordAuthor | Single particle analysis | - |
dc.subject.keywordAuthor | Low-Z particle electron probe X-ray microanalysis | - |
dc.subject.keywordAuthor | Aerosol analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.