Multiple Modality gamma-Ray Imager Using LaCl3(Ce) Scintillators With Active Collimation Method
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Wonho | - |
dc.contributor.author | Jo, Ajin | - |
dc.contributor.author | Yoon, Changyeon | - |
dc.date.accessioned | 2021-09-08T02:49:19Z | - |
dc.date.available | 2021-09-08T02:49:19Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2010-06 | - |
dc.identifier.issn | 0018-9499 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/116362 | - |
dc.description.abstract | Multiple modality gamma-ray imaging using mechanical and electronic collimation with different detection methods was proposed and tested by simulation. Although conventional mechanical collimators, which are made from high atomic number and density materials, passively filter the incident radiation, the mechanical collimator reported in this study consisted of LaCl3(Ce) scintillators, which actively collimate the radiation and are used as the 1st detector of an electronic collimator to reconstruct a Compton image. A detector box made from six planar LaCl3(Ce) scintillators was positioned behind the active collimator. The LaCl3(Ce) scintillator arrays used as the active collimator and box detector consisted of voxels, each 2 mm x 2 mm x 5 mm(3) in size. A combination of active collimators and box detectors can produce multiple modalities for both mechanical and electronic collimation. The information from each modality was combined effectively using the maximum likelihood expectation maximization (MLEM) method. Therefore, a reconstructed image from multiple modalities has inherently higher efficiency than each conventional modality. The reconstructed images were evaluated using the resolution-variance curve as a quantitative method. Although mechanical collimation is effective at low gamma-ray energy and electronic collimation shows high performance at high gamma-ray energy, multiple modalities are superior to the conventional single modalities for intermediate gamma-ray energies (364 keV). The angular resolution and absolute efficiency were calculated for each modality and source energy. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | EMISSION COMPUTED-TOMOGRAPHY | - |
dc.subject | CAMERA | - |
dc.title | Multiple Modality gamma-Ray Imager Using LaCl3(Ce) Scintillators With Active Collimation Method | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Wonho | - |
dc.identifier.doi | 10.1109/TNS.2010.2043539 | - |
dc.identifier.wosid | 000278812200049 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.57, no.3, pp.1396 - 1403 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON NUCLEAR SCIENCE | - |
dc.citation.title | IEEE TRANSACTIONS ON NUCLEAR SCIENCE | - |
dc.citation.volume | 57 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 1396 | - |
dc.citation.endPage | 1403 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordPlus | EMISSION COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | CAMERA | - |
dc.subject.keywordAuthor | Compton camera | - |
dc.subject.keywordAuthor | gamma camera | - |
dc.subject.keywordAuthor | multiple modality | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.