The diagnostic value of the sagittal multiplanar reconstruction CT images for nasal bone fractures
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, B. H. | - |
dc.contributor.author | Seo, H. S. | - |
dc.contributor.author | Kim, A. -Y. | - |
dc.contributor.author | Lee, Y. S. | - |
dc.contributor.author | Lee, Y. H. | - |
dc.contributor.author | Suh, S. -I. | - |
dc.contributor.author | Lee, D. H. | - |
dc.date.accessioned | 2021-09-08T04:07:51Z | - |
dc.date.available | 2021-09-08T04:07:51Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2010-04 | - |
dc.identifier.issn | 0009-9260 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/116698 | - |
dc.description.abstract | AIM: To compare the diagnostic performance of sagittal multiplanar reconstruction (MPR) images and axial images for the detection of a nasal bone fracture. MATERIALS AND METHODS: This prospective study included 533 consecutive patients who underwent three-dimensional images with 64-section multidetector-row CT for the evaluation of a facial bone fracture between June 2007 and May 2008 (366 males; 167 females; mean age standard deviation 31.1 +/- 21.2 years; age range 1-92 years). Two observers independently scored the possibility of a nasal bone fracture on axial and sagittal images. Receiver operating characteristic (ROC) curve analysis was performed. RESULTS: The Az values of the sagittal images were higher than those of the axial images for both observers (p = 0.002 and 0.010, respectively) with higher accuracy (p < 0.001 and 0.016, respectively). The sensitivities of sagittal images were superior to those of axial images, especially for type 1 simple nasal bone fractures with no or minimal displacement (observer 1, 98.6 versus 72.8%; observer 2, 84.9 versus 71%). CONCLUSION: Sagittal MPR facial bone CT images provided superior diagnostic performance, and their addition to axial images is useful for the evaluation of nasal bone fractures. (c) 2010 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | W B SAUNDERS CO LTD | - |
dc.subject | 3-DIMENSIONAL COMPUTED-TOMOGRAPHY | - |
dc.subject | MULTIDETECTOR ROW CT | - |
dc.subject | CORONAL REFORMATIONS | - |
dc.subject | ISOTROPIC VOXELS | - |
dc.subject | MANAGEMENT | - |
dc.subject | RADIOGRAPHY | - |
dc.subject | RESOLUTION | - |
dc.subject | SURFACE | - |
dc.subject | TRAUMA | - |
dc.title | The diagnostic value of the sagittal multiplanar reconstruction CT images for nasal bone fractures | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, B. H. | - |
dc.contributor.affiliatedAuthor | Seo, H. S. | - |
dc.contributor.affiliatedAuthor | Lee, Y. H. | - |
dc.contributor.affiliatedAuthor | Suh, S. -I. | - |
dc.identifier.doi | 10.1016/j.crad.2009.12.006 | - |
dc.identifier.scopusid | 2-s2.0-77949567252 | - |
dc.identifier.wosid | 000277223000007 | - |
dc.identifier.bibliographicCitation | CLINICAL RADIOLOGY, v.65, no.4, pp.308 - 314 | - |
dc.relation.isPartOf | CLINICAL RADIOLOGY | - |
dc.citation.title | CLINICAL RADIOLOGY | - |
dc.citation.volume | 65 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 308 | - |
dc.citation.endPage | 314 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | 3-DIMENSIONAL COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | MULTIDETECTOR ROW CT | - |
dc.subject.keywordPlus | CORONAL REFORMATIONS | - |
dc.subject.keywordPlus | ISOTROPIC VOXELS | - |
dc.subject.keywordPlus | MANAGEMENT | - |
dc.subject.keywordPlus | RADIOGRAPHY | - |
dc.subject.keywordPlus | RESOLUTION | - |
dc.subject.keywordPlus | SURFACE | - |
dc.subject.keywordPlus | TRAUMA | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.