Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A rapid performance diagnosis of seawater reverse osmosis membranes: simulation approach

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Young Geun-
dc.contributor.authorKim, Do Yeon-
dc.contributor.authorKim, Yu Chang-
dc.contributor.authorLee, Yun Seok-
dc.contributor.authorJung, Da Hee-
dc.contributor.authorPark, Minkyu-
dc.contributor.authorPark, Sang-Jin-
dc.contributor.authorLee, Sangho-
dc.contributor.authorYang, Dae Ryook-
dc.contributor.authorKim, Joon Ha-
dc.date.accessioned2021-09-08T04:42:02Z-
dc.date.available2021-09-08T04:42:02Z-
dc.date.created2021-06-11-
dc.date.issued2010-03-
dc.identifier.issn1944-3994-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/116852-
dc.description.abstractRecovery and salt rejection rate, which are directly related to the membrane properties and operating conditions (i.e., feed flow rate, pressure, temperature, and TDS concentration), are two main indicators for evaluating the performance of a reverse osmosis (RO) membrane process. A simple and rapid test with minimum data is inevitably requested to diagnose membrane performance at a certain operating conditions, because experiments at all operating conditions are inefficient and consumable work in the view of cost as well as man-hour. In this study, permeate flow rate and TDS concentration of three kinds of commercial RO membranes were carefully examined under various operating conditions [i.e., feed pressure (45-65 kgf/cm(2)) and temperature (5-30 degrees C)]. Based on the experimental data, membrane resistance models including temperature and pressure correction factors were developed for the rapid diagnosis of SWRO membrane performances. As a result, the models developed in this study have good agreements between observed and simulated data. Based on the procedure in this study, the performance of any type of RO membranes can be rapidly examined by simple model parameter inputs. Furthermore, the developed diagnosis tool for performance test of SWRO membranes can be practically applied to build database of membrane performance for designing the SWRO process with minimum data as well as to reduce the cost and effort for data acquisition.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherDESALINATION PUBL-
dc.subjectCONCENTRATION POLARIZATION-
dc.titleA rapid performance diagnosis of seawater reverse osmosis membranes: simulation approach-
dc.typeArticle-
dc.contributor.affiliatedAuthorYang, Dae Ryook-
dc.identifier.doi10.5004/dwt.2010.1661-
dc.identifier.scopusid2-s2.0-77954238683-
dc.identifier.wosid000276641700003-
dc.identifier.bibliographicCitationDESALINATION AND WATER TREATMENT, v.15, no.1-3, pp.11 - 19-
dc.relation.isPartOfDESALINATION AND WATER TREATMENT-
dc.citation.titleDESALINATION AND WATER TREATMENT-
dc.citation.volume15-
dc.citation.number1-3-
dc.citation.startPage11-
dc.citation.endPage19-
dc.type.rimsART-
dc.type.docTypeArticle; Proceedings Paper-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaWater Resources-
dc.relation.journalWebOfScienceCategoryEngineering, Chemical-
dc.relation.journalWebOfScienceCategoryWater Resources-
dc.subject.keywordPlusCONCENTRATION POLARIZATION-
dc.subject.keywordAuthorReverse osmosis membrane-
dc.subject.keywordAuthorMembrane resistance model-
dc.subject.keywordAuthorTemperature correction factor-
dc.subject.keywordAuthorPressure correction factor-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE