Air-side heat transfer characteristics of spiral-type circular fin-tube heat exchangers
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Mooyeon | - |
dc.contributor.author | Kang, Taehyung | - |
dc.contributor.author | Kim, Yonchan | - |
dc.date.accessioned | 2021-09-08T04:52:27Z | - |
dc.date.available | 2021-09-08T04:52:27Z | - |
dc.date.issued | 2010-03 | - |
dc.identifier.issn | 0140-7007 | - |
dc.identifier.issn | 1879-2081 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/116911 | - |
dc.description.abstract | The objective of this study is to investigate the air-side heat transfer characteristics of spiral-type circular fin-tube heat exchangers used as evaporators in household refrigerators. The j-factors of the tested heat exchangers under non-frosting conditions were measured by varying the fin pitch, number of tube rows, and fin alignment. The j-factors of the spiral-type circular fin-tube heat exchangers were analyzed as a function of heat exchanger geometries and then compared with those of the flat plate fin-tube heat exchangers with discrete fins. Two empirical correlations of the j-factors were developed separately for the inline and the staggered fin alignment as a function of the Reynolds number, number of tube rows, and dimensionless fin pitch normalized by the hydraulic diameter, The mean deviation of the predictions using the present correlations from the measured data was 4.78% for the inline fin alignment and 6.02% for the staggered fin alignment. (C) 2009 Elsevier Ltd and IIR. All rights reserved. | - |
dc.format.extent | 8 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | ELSEVIER SCI LTD | - |
dc.title | Air-side heat transfer characteristics of spiral-type circular fin-tube heat exchangers | - |
dc.type | Article | - |
dc.publisher.location | 영국 | - |
dc.identifier.doi | 10.1016/j.ijrefrig.2009.09.019 | - |
dc.identifier.scopusid | 2-s2.0-74149089367 | - |
dc.identifier.wosid | 000274889800012 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, v.33, no.2, pp 313 - 320 | - |
dc.citation.title | INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | - |
dc.citation.volume | 33 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 313 | - |
dc.citation.endPage | 320 | - |
dc.type.docType | Article | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | sci | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Thermodynamics | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.subject.keywordPlus | FRICTION CHARACTERISTICS | - |
dc.subject.keywordPlus | PLATE-FIN | - |
dc.subject.keywordAuthor | Chiller | - |
dc.subject.keywordAuthor | Heat exchanger | - |
dc.subject.keywordAuthor | Finned tube | - |
dc.subject.keywordAuthor | Spiral | - |
dc.subject.keywordAuthor | Geometry | - |
dc.subject.keywordAuthor | Experiment | - |
dc.subject.keywordAuthor | Heat transfer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.