Estimate of the Real-Time Respiratory Simulation System in CyberKnife Image-Guided Radiosurgery

Full metadata record
DC Field Value Language
dc.contributor.authorMin, Chul Kee-
dc.contributor.authorChung, Weon Kuu-
dc.contributor.authorLee, Suk-
dc.contributor.authorKim, Chul Yong-
dc.contributor.authorShim, Jang Bo-
dc.contributor.authorHuh, HyunDo-
dc.contributor.authorLee, SangHoon-
dc.contributor.authorCho, Sam Ju-
dc.contributor.authorLim, Sangwook-
dc.contributor.authorCho, Kwang Hwan-
dc.contributor.authorLim, Jong Soo-
dc.contributor.authorKwon, Soo Il-
dc.date.accessioned2021-09-08T05:56:12Z-
dc.date.available2021-09-08T05:56:12Z-
dc.date.created2021-06-11-
dc.date.issued2010-01-
dc.identifier.issn0374-4884-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/117206-
dc.description.abstractThe purpose of this study was to evaluate the target accuracy according to the movement with respiration of an actual patient in a quantitative way by developing a real-time respiratory simulation system (MISS), including a patient customized 3D moving phantom. The real-time respiratory simulation system (RRSS) consists of two robots in order to implement both the movement of body surfaces and the movement of internal organs caused by respiration. The quantitative evaluation for the 31) movement of the RRSS was performed using a real-time laser displacement sensor for each axis. The average difference in the static movement of the MISS was about 0.01 similar to 0.06 mm. Also, in the evaluation of the dynamic movement by producing a formalized sine wave with the phase of four seconds per cycle, the difference between the measured and the calculated values for each cycle length in the robot that was in charge of body surfaces and the robot that was in charge of the movement of internal tumors showed 0.10 similar to 0.55 seconds, and the correlation coefficients between the calculated and the measured values were 0.998 similar to 0.999. The differences between the maximum and the minimum amplitudes were 0.01 similar to 0.06 mm, and the reproducibility was within +/- 0.5 mm. In the case of the application and non-application of respiration, the target errors were -0.05 similar to 1.05 mm and -0.13 similar to 0.74 mm, respectively, and the entire target errors were 1.30 mm and 0.79 mm, respectively. Based oil the accuracy in the RRSS system, various respiration patterns of patients can be reproduced in real-time. Also, this system dan be used as an optimal too] for applying patient customized accuracy management in image-guided radiosurgery.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectBREATHING CONTROL ABC-
dc.subjectORGAN MOTION-
dc.subjectTUMOR MOTION-
dc.subjectLUNG-
dc.subjectRADIOTHERAPY-
dc.subjectIMMOBILIZATION-
dc.subjectMOVEMENT-
dc.subjectPRECISE-
dc.subjectPATTERN-
dc.subjectERRORS-
dc.titleEstimate of the Real-Time Respiratory Simulation System in CyberKnife Image-Guided Radiosurgery-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Suk-
dc.contributor.affiliatedAuthorKim, Chul Yong-
dc.identifier.doi10.3938/jkps.56.164-
dc.identifier.scopusid2-s2.0-77954854226-
dc.identifier.wosid000273768200029-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.56, no.1, pp.164 - 170-
dc.relation.isPartOfJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.citation.volume56-
dc.citation.number1-
dc.citation.startPage164-
dc.citation.endPage170-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001429031-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryPhysics, Multidisciplinary-
dc.subject.keywordPlusBREATHING CONTROL ABC-
dc.subject.keywordPlusORGAN MOTION-
dc.subject.keywordPlusTUMOR MOTION-
dc.subject.keywordPlusLUNG-
dc.subject.keywordPlusRADIOTHERAPY-
dc.subject.keywordPlusIMMOBILIZATION-
dc.subject.keywordPlusMOVEMENT-
dc.subject.keywordPlusPRECISE-
dc.subject.keywordPlusPATTERN-
dc.subject.keywordPlusERRORS-
dc.subject.keywordAuthorCyberKnife-
dc.subject.keywordAuthorRRSS (Real-time respiratory simulation system)-
dc.subject.keywordAuthorSynchrony-
dc.subject.keywordAuthorTracking-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chul Yong photo

Kim, Chul Yong
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE