The Efficacy of Two Electrodes Radiofrequency Technique: Comparison Study Using a Cadaveric Interspinous Ligament and Temperature Measurement Using Egg White
- Authors
- Lee, Chang-Hyung; Derby, Richard; Choi, Hyun-Seok; Lee, Sang-Heon; Kim, Se Hoon; Kang, Yoon Kyu
- Issue Date
- 1월-2010
- Publisher
- AM SOC INTERVENTIONAL PAIN PHYSICIANS
- Keywords
- Rhizotomy; radiofrequency neurotomy; 2 needles; facet joint pain; low back pain; cadaveric tissue
- Citation
- PAIN PHYSICIAN, v.13, no.1, pp.43 - 49
- Indexed
- SCIE
SCOPUS
- Journal Title
- PAIN PHYSICIAN
- Volume
- 13
- Number
- 1
- Start Page
- 43
- End Page
- 49
- URI
- https://scholar.korea.ac.kr/handle/2021.sw.korea/117296
- ISSN
- 1533-3159
- Abstract
- Background: One technique in radiofrequency neurotomies uses 2 electrodes that are simultaneously placed to lie parallel to one another. Comparing lesions on cadaveric interspinous ligament tissue and measuring the temperature change in egg white allows us to accurately measure quantitatively the area of the lesion. Methods: Fresh cadaver spinal tissue and egg white tissue were used. A series of samples were prepared with the electrodes placed 1 to 7 mm apart. Using the needle electrodes were heated in sequential or simultaneous radiofrequency, order and the distance of the escaped lesion area and temperature were measured. Results: Samples of cadaver interspinous ligament showed sequential heating of the needles limits the placement of the needle electrodes up to 2 mm apart from each other and up to 4 mm apart when heated simultaneously. The temperature at the escaped lesion area decreased according to the distance for egg white. There was a significant difference in temperature at the escaped lesion area up to 6 mm apart and the temperature was above 50 degrees C up to 5 mm in simultaneous lesion and 3 mm in the sequential lesion. Limitations:: The limitations of this study include cadaveric experimentation and use of intraspinous ligament rather than medial branch of the dorsal ramus which is difficult to identify. Conclusion: Heating the 2 electrodes simultaneously appears to coagulate a wider area and potentially produce better results in less time.
- Files in This Item
- There are no files associated with this item.
- Appears in
Collections - College of Medicine > Department of Medical Science > 1. Journal Articles
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.