PERFORMANCE CHARACTERISTICS OF A BYPASS TWO-CIRCUIT REFRIGERATION CYCLE DESIGNED FOR REFRIGERATORS
DC Field | Value | Language |
---|---|---|
dc.contributor.author | HAE WON JUNG | - |
dc.contributor.author | WONJAE YOON | - |
dc.contributor.author | HYUN JOON CHUNG | - |
dc.contributor.author | 김용찬 | - |
dc.date.accessioned | 2021-09-08T08:51:16Z | - |
dc.date.available | 2021-09-08T08:51:16Z | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 2010-1325 | - |
dc.identifier.issn | 2010-1333 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118184 | - |
dc.description.abstract | In this study, the performance characteristics of a bypass two-circuit refrigeration cycle designed for refrigerators were investigated in a bench scale refrigeration system. The bypass two-circuit refrigeration cycle with R600a operates in two modes of refrigerator/freezer-mode (RF-mode) and freezer only-mode (F only-mode) by switching refrigerant flow path. The performance of the bypass two-circuit refrigeration cycle was measured by varying the condenser capacity, the length of the suction line heat exchanger (SLHX), and the refrigerant charge amount with adoption of the refrigerant storage vessel. The COPs of the bypass two-circuit refrigeration cycle at RF-mode and F only-mode increased by 10% and 17%, respectively, with the increase of the condenser capacity and SLHX length. In addition, the COP of the system at F only-mode increased by 10% with the adoption of the refrigerant storage vessel. | - |
dc.format.extent | 7 | - |
dc.language | 영어 | - |
dc.language.iso | ENG | - |
dc.publisher | 대한설비공학회 | - |
dc.title | PERFORMANCE CHARACTERISTICS OF A BYPASS TWO-CIRCUIT REFRIGERATION CYCLE DESIGNED FOR REFRIGERATORS | - |
dc.title.alternative | PERFORMANCE CHARACTERISTICS OF A BYPASS TWO-CIRCUIT REFRIGERATION CYCLE DESIGNED FOR REFRIGERATORS | - |
dc.type | Article | - |
dc.publisher.location | 싱가폴 | - |
dc.identifier.bibliographicCitation | International Journal of Air-Conditioning and Refrigeration, v.18, no.2, pp 141 - 147 | - |
dc.citation.title | International Journal of Air-Conditioning and Refrigeration | - |
dc.citation.volume | 18 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 141 | - |
dc.citation.endPage | 147 | - |
dc.identifier.kciid | ART001494745 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Bypass two-circuit refrigeration cycle | - |
dc.subject.keywordAuthor | refrigerator | - |
dc.subject.keywordAuthor | refrigerant charge amount | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.