Role of Cardiac Multidetector Computed Tomography in Acute Ischemic Stroke: A Preliminary Report
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ko, Sang-Bae | - |
dc.contributor.author | Choi, Sang Il | - |
dc.contributor.author | Chun, Eun Ju | - |
dc.contributor.author | Ko, Youngchai | - |
dc.contributor.author | Park, Jung-Hyun | - |
dc.contributor.author | Lee, Sook-Jin | - |
dc.contributor.author | Lee, Juneyoung | - |
dc.contributor.author | Han, Moon-Ku | - |
dc.contributor.author | Bae, Hee-Joon | - |
dc.date.accessioned | 2021-09-08T10:00:02Z | - |
dc.date.available | 2021-09-08T10:00:02Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2010 | - |
dc.identifier.issn | 1015-9770 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118552 | - |
dc.description.abstract | Background and Purpose: Cardiac multidetector computed tomography (MDCT) is less dependent upon the patient's condition and may be valuable in the diagnosis of embolic sources when the patient's cooperation is limited due to a neurologic deficit. However, its role has never been validated in acute stroke patients whose stroke mechanism is assumed to be embolic. Methods: Consecutive patients who were admitted with acute ischemic stroke from May 1, 2007 to November 30, 2007 were included in this study. Inclusion criteria were (1) any cardiac evidence of high-risk embolic sources for cerebral embolism, or (2) radiological or (3) clinical evidence of embolic stroke. All patients underwent transthoracic echocardiography first, and then cardiac MDCT or transesophageal echocardiography (TEE) was attempted, if possible. The results and feasibility of cardiac MDCT and TEE were compared. Results: One hundred and forty-three patients met the inclusion criteria. Cardiac MDCT was performed in 124 patients (86.7%), TEE in 83 patients (57.3%), whereas 75 patients (52.4%) underwent both studies. Renal insufficiency for cardiac MDCT and lack of cooperation for TEE were found to be the most impeding factors. Among the patients with both evaluations, cardiac MDCT identified a high-risk intracardiac embolic source in 8 and an extracardiac source in 20, while TEE found an intracardiac source in 1 and an extracardiac source in 7. Statistically significant differences were found with respect to detecting cardioembolic sources and high-risk aortic atheroma. Conclusions: Cardiac MDCT is a feasible and accurate diagnostic tool for embolic sources in an acute stroke setting. Copyright (C) 2010 S. Karger AG, Basel | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KARGER | - |
dc.subject | LEFT ATRIAL APPENDAGE | - |
dc.subject | PATENT FORAMEN OVALE | - |
dc.subject | TRANSESOPHAGEAL ECHOCARDIOGRAPHY | - |
dc.subject | CT ANGIOGRAPHY | - |
dc.subject | FILLING DEFECTS | - |
dc.subject | CLASSIFICATION | - |
dc.subject | THROMBUS | - |
dc.subject | 16-SLICE | - |
dc.subject | DISEASE | - |
dc.title | Role of Cardiac Multidetector Computed Tomography in Acute Ischemic Stroke: A Preliminary Report | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Juneyoung | - |
dc.identifier.doi | 10.1159/000278926 | - |
dc.identifier.scopusid | 2-s2.0-75549084152 | - |
dc.identifier.wosid | 000277048400001 | - |
dc.identifier.bibliographicCitation | CEREBROVASCULAR DISEASES, v.29, no.4, pp.313 - 320 | - |
dc.relation.isPartOf | CEREBROVASCULAR DISEASES | - |
dc.citation.title | CEREBROVASCULAR DISEASES | - |
dc.citation.volume | 29 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 313 | - |
dc.citation.endPage | 320 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.relation.journalWebOfScienceCategory | Peripheral Vascular Disease | - |
dc.subject.keywordPlus | LEFT ATRIAL APPENDAGE | - |
dc.subject.keywordPlus | PATENT FORAMEN OVALE | - |
dc.subject.keywordPlus | TRANSESOPHAGEAL ECHOCARDIOGRAPHY | - |
dc.subject.keywordPlus | CT ANGIOGRAPHY | - |
dc.subject.keywordPlus | FILLING DEFECTS | - |
dc.subject.keywordPlus | CLASSIFICATION | - |
dc.subject.keywordPlus | THROMBUS | - |
dc.subject.keywordPlus | 16-SLICE | - |
dc.subject.keywordPlus | DISEASE | - |
dc.subject.keywordAuthor | Cardiac multidetector computed tomography | - |
dc.subject.keywordAuthor | Transesophageal echocardiography | - |
dc.subject.keywordAuthor | Acute ischemic stroke | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.