Development of an Algorithm to Regulate Pump Output for a Closed Air-Loop Type Pneumatic Biventricular Assist Device
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Nam, KyoungWon | - |
dc.contributor.author | Lee, Jung Joo | - |
dc.contributor.author | Hwang, Chang Mo | - |
dc.contributor.author | Choi, Jaesoon | - |
dc.contributor.author | Choi, Hyuk | - |
dc.contributor.author | Choi, SeongWook | - |
dc.contributor.author | Sun, Kyung | - |
dc.date.accessioned | 2021-09-08T10:52:16Z | - |
dc.date.available | 2021-09-08T10:52:16Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2009-12 | - |
dc.identifier.issn | 0160-564X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118764 | - |
dc.description.abstract | The closed air space-type of extracorporeal pneumatic ventricular assist device (VAD) developed by the Korea Artificial Organ Center utilizes a bellows-transforming mechanism to generate the air pressure required to pump blood. This operating mechanism can reduce the size and weight of the driving unit; however, the output of the blood pump can be affected by the pressure loading conditions of the blood sac. Therefore, to guarantee a proper pump output level, regardless of the pressure loading conditions that vary over time, automatic pump output regulation of the blood pump is required. We describe herein a pump output regulation algorithm that was developed to maintain pump output around a reference level against various afterload pressures, and verified the pump performance in vitro. Based on actual operating conditions in animal experiments, the pumping rate was limited to 40-84 beats per minute, and the afterload pressure was limited to 80-150 mm Hg. The tested reference pump output was 4.0 L/min. During experiments, the pump output was successfully and automatically regulated within the preset area regardless of the varying afterload conditions. The results of this preliminary experiment can be used as the basis for an automatic control algorithm that can enhance the stability and reliability of the applied VAD. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | LEFT-VENTRICULAR ASSIST | - |
dc.subject | ARTIFICIAL-HEART | - |
dc.subject | PORTABLE DRIVER | - |
dc.title | Development of an Algorithm to Regulate Pump Output for a Closed Air-Loop Type Pneumatic Biventricular Assist Device | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Jaesoon | - |
dc.contributor.affiliatedAuthor | Sun, Kyung | - |
dc.identifier.doi | 10.1111/j.1525-1594.2009.00809.x | - |
dc.identifier.scopusid | 2-s2.0-74049123887 | - |
dc.identifier.wosid | 000272835600003 | - |
dc.identifier.bibliographicCitation | ARTIFICIAL ORGANS, v.33, no.12, pp.1063 - 1068 | - |
dc.relation.isPartOf | ARTIFICIAL ORGANS | - |
dc.citation.title | ARTIFICIAL ORGANS | - |
dc.citation.volume | 33 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 1063 | - |
dc.citation.endPage | 1068 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Transplantation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Transplantation | - |
dc.subject.keywordPlus | LEFT-VENTRICULAR ASSIST | - |
dc.subject.keywordPlus | ARTIFICIAL-HEART | - |
dc.subject.keywordPlus | PORTABLE DRIVER | - |
dc.subject.keywordAuthor | Pneumatic ventricular assist device | - |
dc.subject.keywordAuthor | Afterload pressure estimation | - |
dc.subject.keywordAuthor | Pump output estimation | - |
dc.subject.keywordAuthor | Pump output regulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.