Polymer-based flexible tactile sensor up to 32 x 32 arrays integrated with interconnection terminals
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Kunnyun | - |
dc.contributor.author | Lee, Kang Ryeol | - |
dc.contributor.author | Kim, Won Hyo | - |
dc.contributor.author | Park, Kwang-Bum | - |
dc.contributor.author | Kim, Tae-Hyung | - |
dc.contributor.author | Kim, Jin-Sang | - |
dc.contributor.author | Pak, James Jungho | - |
dc.date.accessioned | 2021-09-08T10:56:42Z | - |
dc.date.available | 2021-09-08T10:56:42Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2009-12 | - |
dc.identifier.issn | 0924-4247 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118787 | - |
dc.description.abstract | A polymer-based flexible tactile sensor array integrated with interconnection terminals was fabricated with polymer MEMS technologies and electroplating. The tactile sensing arrays were made as 4 x 4,8 x 8, 16 x 16 and 32 x 32 sensing elements connected with a pluggable connector. Both the tactile sensor arrays and the interconnection terminals were fabricated together on the same polymer substrate in order to integrate them as a sensor module. The tactile sensor array with FFC (flexible flat cable) can be easily connected with the sensor array mounting PCB board by inserting the flexible cable into the pluggable connector socket on the board. The number and pitch of the fabricated interconnection terminals for 32 x 32 arrays were 68 and 500 mu m, respectively. Continuous normal force ranging 0-1 N was applied to a unit tactile sensor for evaluating the tactile sensor characteristics through the integrated interconnection terminals. The measured resistance increased linearly with normal force in the range of 0-0.6 N but the resistance variation rate decreased above 0.6 N. The variation rate of the resistance is about 2.0%/N in the range of 0-0.6 N and 1%/N in the range of 0.6-1 N. The characterization of the tactile sensor array for the rod bar and a fingertip was successfully evaluated using the custom designed controller and the window-based 3D display software. (C) 2009 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.title | Polymer-based flexible tactile sensor up to 32 x 32 arrays integrated with interconnection terminals | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Kunnyun | - |
dc.contributor.affiliatedAuthor | Pak, James Jungho | - |
dc.identifier.doi | 10.1016/j.sna.2009.08.015 | - |
dc.identifier.scopusid | 2-s2.0-71949101125 | - |
dc.identifier.wosid | 000272563900002 | - |
dc.identifier.bibliographicCitation | SENSORS AND ACTUATORS A-PHYSICAL, v.156, no.2, pp.284 - 291 | - |
dc.relation.isPartOf | SENSORS AND ACTUATORS A-PHYSICAL | - |
dc.citation.title | SENSORS AND ACTUATORS A-PHYSICAL | - |
dc.citation.volume | 156 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 284 | - |
dc.citation.endPage | 291 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordAuthor | Flexible tactile sensor array | - |
dc.subject.keywordAuthor | Polymer MEMS | - |
dc.subject.keywordAuthor | Interconnection terminals | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.