Experimental Investigation of Deck Plate System with Non-Welding Truss Type Deformed Steel Wires (TOX Deck Plate Slab)
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Young-Ju | - |
dc.contributor.author | Oh, Sang-Hoon | - |
dc.contributor.author | Yoon, Myung-Ho | - |
dc.contributor.author | Lee, Young-Hak | - |
dc.contributor.author | Kim, Heecheul | - |
dc.contributor.author | Byon, Eunhyuk | - |
dc.date.accessioned | 2021-09-08T11:07:28Z | - |
dc.date.available | 2021-09-08T11:07:28Z | - |
dc.date.created | 2021-06-11 | - |
dc.date.issued | 2009-12 | - |
dc.identifier.issn | 1598-2351 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/118846 | - |
dc.description.abstract | On the bases of a decreased construction period and convenience of construction, the steel deck plate system has been widely used in the construction field in Korea. In particular, due to its good stiffness and economic considerations, the steel-wire-integrated deck plate system (or truss deck plate system) has become very popular in recent years. But while it offers many advantages, the truss deck plate system has a critical defect: rust forms in the welding joints between the lattice steel wire and the deck plate, resulting in the cracking of these welding joints and water leakage. To address these problems, the TOX deck plate system, a new type of truss deck plate system that does not require welding and does not rust, is proposed in this paper. Tests have been conducted oil 15 specimens to evaluate the structural safety of the proposed deck plate system during the construction stage. The test parameters were as follows: the depth of the slab, the length of the span, the diameters of the top, bottom, and lattice steel wire, and the material properties of the zinc-coated steel sheets. The test results show that the TOX deck plate system can guarantee structural safety owing to its deflection and strength. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN SOC STEEL CONSTRUCTION-KSSC | - |
dc.subject | COMPOSITE SLAB | - |
dc.title | Experimental Investigation of Deck Plate System with Non-Welding Truss Type Deformed Steel Wires (TOX Deck Plate Slab) | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Young-Ju | - |
dc.identifier.doi | 10.1007/BF03249505 | - |
dc.identifier.wosid | 000273592900006 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF STEEL STRUCTURES, v.9, no.4, pp.315 - 327 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
dc.citation.title | INTERNATIONAL JOURNAL OF STEEL STRUCTURES | - |
dc.citation.volume | 9 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 315 | - |
dc.citation.endPage | 327 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001408994 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.subject.keywordPlus | COMPOSITE SLAB | - |
dc.subject.keywordAuthor | deck plate | - |
dc.subject.keywordAuthor | construction stage | - |
dc.subject.keywordAuthor | zinc-coated steel sheets | - |
dc.subject.keywordAuthor | structural safety | - |
dc.subject.keywordAuthor | floor member | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.