Optimizing the Circuit of a Pulsatile Extracorporeal Life Support System in Terms of Energy Equivalent Pressure and Surplus Hemodynamic Energy

Full metadata record
DC Field Value Language
dc.contributor.authorLim, Choon Hak-
dc.contributor.authorYang, Sung-
dc.contributor.authorChoi, Jae-Wook-
dc.contributor.authorSun, Kyung-
dc.date.accessioned2021-09-08T11:52:49Z-
dc.date.available2021-09-08T11:52:49Z-
dc.date.created2021-06-11-
dc.date.issued2009-11-
dc.identifier.issn0160-564X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/118963-
dc.description.abstractThe nonpulsatile blood flow obtained using standard cardiopulmonary bypass (CPB) circuits is still generally considered an acceptable, nonphysiologic compromise with few disadvantages. However, numerous reports have concluded that pulsatile perfusion during CPB achieves better multiorgan response postoperatively. Furthermore, pulsatile flow during CPB has been consistently recommended in pediatric and high-risk patients. However, most (80%) of the total hemodynamic energy generated by a pulsatile pump is absorbed by the components of the extracorporeal circuit and only a small portion of the pulsatile energy is delivered to the patient. Therefore, we considered that optimizations of CPB unit and extracorporeal life support (ECLS) system circuit components were needed to deliver sufficient pulsatile flow. In addition, energy equivalent pressure, surplus hemodynamic energy, and total hemodynamic energy, calculated using pressure and flow waveforms, were used to evaluate the pulsatilities of pulsatile CPB and ECLS systems.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectHL-20 ROLLER-PUMP-
dc.subjectCARDIOPULMONARY BYPASS-
dc.subjectBLOOD-FLOW-
dc.subjectNONPULSATILE PERFUSION-
dc.subjectINTRAAORTIC BALLOON-
dc.subjectPRECISE QUANTIFICATION-
dc.subjectCENTRIFUGAL PUMP-
dc.subjectCARDIOPLEGIC ARREST-
dc.subjectWAVE-FORMS-
dc.subjectCPB-
dc.titleOptimizing the Circuit of a Pulsatile Extracorporeal Life Support System in Terms of Energy Equivalent Pressure and Surplus Hemodynamic Energy-
dc.typeArticle-
dc.contributor.affiliatedAuthorLim, Choon Hak-
dc.contributor.affiliatedAuthorSun, Kyung-
dc.identifier.doi10.1111/j.1525-1594.2009.00887.x-
dc.identifier.scopusid2-s2.0-70450245144-
dc.identifier.wosid000272127800022-
dc.identifier.bibliographicCitationARTIFICIAL ORGANS, v.33, no.11, pp.1015 - 1020-
dc.relation.isPartOfARTIFICIAL ORGANS-
dc.citation.titleARTIFICIAL ORGANS-
dc.citation.volume33-
dc.citation.number11-
dc.citation.startPage1015-
dc.citation.endPage1020-
dc.type.rimsART-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.subject.keywordPlusHL-20 ROLLER-PUMP-
dc.subject.keywordPlusCARDIOPULMONARY BYPASS-
dc.subject.keywordPlusBLOOD-FLOW-
dc.subject.keywordPlusNONPULSATILE PERFUSION-
dc.subject.keywordPlusINTRAAORTIC BALLOON-
dc.subject.keywordPlusPRECISE QUANTIFICATION-
dc.subject.keywordPlusCENTRIFUGAL PUMP-
dc.subject.keywordPlusCARDIOPLEGIC ARREST-
dc.subject.keywordPlusWAVE-FORMS-
dc.subject.keywordPlusCPB-
dc.subject.keywordAuthorEnergy equivalent pressure-
dc.subject.keywordAuthorNonpulsatile-
dc.subject.keywordAuthorPulsatile-
dc.subject.keywordAuthorSurplus hemodynamic energy-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Choon Hak photo

Lim, Choon Hak
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE