Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Absolute CD4(+) Cell Count Using a Plastic Microchip and a Microscopic Cell Counter

Full metadata record
DC Field Value Language
dc.contributor.authorBae, Sook Young-
dc.contributor.authorPark, Hae Chul-
dc.contributor.authorOh, Jun Seo-
dc.contributor.authorYoon, Soo-Young-
dc.contributor.authorPark, Dae Won-
dc.contributor.authorChoi, In Keun-
dc.contributor.authorKim, Hae Joong-
dc.contributor.authorOh, Jong Hyun-
dc.contributor.authorHur, Dae Sung-
dc.contributor.authorChung, Chanil-
dc.contributor.authorChang, Jun Keun-
dc.contributor.authorRobinson, J. Paul-
dc.contributor.authorLim, Chae Seung-
dc.date.accessioned2021-09-08T13:45:48Z-
dc.date.available2021-09-08T13:45:48Z-
dc.date.created2021-06-11-
dc.date.issued2009-09-
dc.identifier.issn1552-4949-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/119356-
dc.description.abstractWe have designed and evaluated the performance of a simple, rapid, and affordable method for counting CD4(+) T-cells with the use of plastic microchips. This new system is an adaptation of a "no-lyse, no-wash," volumetric single platform assay, and absolute CD4(+) counts are determined with the use of a microscopic scanning cell counter. To assess the CD4(+) count test precision and linearity of the system, measured CD4(+) counts were compared with two other reference assays (single and dual platform flow cytometry) with the use of 123 clinical samples including samples obtained from 35 HIV-infected patients, and artificially diluted samples. A correlation between the results from the use of the new method and from the use of the two other reference assays was r = 0.98 for the clinical samples. A dilution test of the new method demonstrated a linearity of r >= 0.99, with coefficients of variation <= 7.6% for all concentration levels. Our findings suggest that the new CD4(+) counting device can be potentially be applied for other diagnostic procedures that measure quantities of characteristic antigens or other materials on cells. (C) 2009 Clinical Cytometry Society-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectPLATFORM IMAGE CYTOMETER-
dc.subjectVOLUMETRIC CAPILLARY CYTOMETRY-
dc.subjectHUMAN-IMMUNODEFICIENCY-VIRUS-
dc.subjectRESOURCE-POOR SETTINGS-
dc.subjectT-LYMPHOCYTES-
dc.subjectHIV-
dc.subjectENUMERATION-
dc.subjectBLOOD-
dc.subjectQUANTITATION-
dc.subjectNUMBERS-
dc.titleAbsolute CD4(+) Cell Count Using a Plastic Microchip and a Microscopic Cell Counter-
dc.typeArticle-
dc.contributor.affiliatedAuthorPark, Hae Chul-
dc.contributor.affiliatedAuthorOh, Jun Seo-
dc.contributor.affiliatedAuthorYoon, Soo-Young-
dc.contributor.affiliatedAuthorPark, Dae Won-
dc.contributor.affiliatedAuthorChoi, In Keun-
dc.contributor.affiliatedAuthorKim, Hae Joong-
dc.contributor.affiliatedAuthorLim, Chae Seung-
dc.identifier.doi10.1002/cyto.b.20470-
dc.identifier.scopusid2-s2.0-74849096381-
dc.identifier.wosid000269426400006-
dc.identifier.bibliographicCitationCYTOMETRY PART B-CLINICAL CYTOMETRY, v.76B, no.5, pp.345 - 353-
dc.relation.isPartOfCYTOMETRY PART B-CLINICAL CYTOMETRY-
dc.citation.titleCYTOMETRY PART B-CLINICAL CYTOMETRY-
dc.citation.volume76B-
dc.citation.number5-
dc.citation.startPage345-
dc.citation.endPage353-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMedical Laboratory Technology-
dc.relation.journalResearchAreaPathology-
dc.relation.journalWebOfScienceCategoryMedical Laboratory Technology-
dc.relation.journalWebOfScienceCategoryPathology-
dc.subject.keywordPlusPLATFORM IMAGE CYTOMETER-
dc.subject.keywordPlusVOLUMETRIC CAPILLARY CYTOMETRY-
dc.subject.keywordPlusHUMAN-IMMUNODEFICIENCY-VIRUS-
dc.subject.keywordPlusRESOURCE-POOR SETTINGS-
dc.subject.keywordPlusT-LYMPHOCYTES-
dc.subject.keywordPlusHIV-
dc.subject.keywordPlusENUMERATION-
dc.subject.keywordPlusBLOOD-
dc.subject.keywordPlusQUANTITATION-
dc.subject.keywordPlusNUMBERS-
dc.subject.keywordAuthorantigens-
dc.subject.keywordAuthorCD4-
dc.subject.keywordAuthorCD4 lymphocyte count-
dc.subject.keywordAuthorflow cytometry-
dc.subject.keywordAuthormicrochip-
dc.subject.keywordAuthorabsolute CD4 count-
dc.subject.keywordAuthormicroscopic cell counter-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hai Joong photo

Kim, Hai Joong
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE