Reoperative Surgical Stabilization of a Painful Nonunited Rib Fracture Using Bone Grafting and a Metal Plate
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Yang Hyun | - |
dc.contributor.author | Kim, Hyun Koo | - |
dc.contributor.author | Kang, Du-Young | - |
dc.contributor.author | Choi, Young Ho | - |
dc.date.accessioned | 2021-09-08T14:16:45Z | - |
dc.date.available | 2021-09-08T14:16:45Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-09 | - |
dc.identifier.issn | 0890-5339 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/119464 | - |
dc.description.abstract | We report a case of a nonunited sixth rib in a patient with multiple rib fractures who underwent internal fixation using a wire and Judet strut 3 times. During the following 3 years, the patient continued to complain of pain and instability. At surgery, a pseudarthrosis between the ends of the sixth rib was excised. A longitudinal gutter crossing the fracture site was fashioned and splinted with an inlay block of cancellous bone grafted from the iliac crest; stabilization was accomplished with a reconstruction plate and screws. The following 2 years of follow-up demonstrated no instability or pain. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.title | Reoperative Surgical Stabilization of a Painful Nonunited Rib Fracture Using Bone Grafting and a Metal Plate | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hyun Koo | - |
dc.identifier.doi | 10.1097/BOT.0b013e3181a16123 | - |
dc.identifier.scopusid | 2-s2.0-69349097415 | - |
dc.identifier.wosid | 000269465000011 | - |
dc.identifier.bibliographicCitation | JOURNAL OF ORTHOPAEDIC TRAUMA, v.23, no.8, pp.605 - 606 | - |
dc.relation.isPartOf | JOURNAL OF ORTHOPAEDIC TRAUMA | - |
dc.citation.title | JOURNAL OF ORTHOPAEDIC TRAUMA | - |
dc.citation.volume | 23 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 605 | - |
dc.citation.endPage | 606 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalResearchArea | Sport Sciences | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Sport Sciences | - |
dc.subject.keywordAuthor | rib | - |
dc.subject.keywordAuthor | fracture | - |
dc.subject.keywordAuthor | nonunion | - |
dc.subject.keywordAuthor | bone graft | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.