A Novel Method for Providing Precise Time Synchronization in a Distributed Control System Using Boundary Clock
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Jae Hun | - |
dc.contributor.author | Kim, Hoon | - |
dc.contributor.author | Wang, Sihai | - |
dc.contributor.author | Lee, Jaehoon | - |
dc.contributor.author | Lee, Hanlim | - |
dc.contributor.author | Hwang, Seongtaek | - |
dc.contributor.author | Cho, Sungdae | - |
dc.contributor.author | Oh, Yunje | - |
dc.contributor.author | Lee, Tae-Jin | - |
dc.date.accessioned | 2021-09-08T15:01:46Z | - |
dc.date.available | 2021-09-08T15:01:46Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-08 | - |
dc.identifier.issn | 0018-9456 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/119536 | - |
dc.description.abstract | We propose and demonstrate a method to provide precise time synchronization in distributed control systems using a boundary clock scheme. The major drawback of the boundary clock scheme is the exponential accumulation of time synchronization error as the number of hops increases. To make the error accumulation linearly increase with the number of hops, we first separate the frequency compensation interval (FCI) and the offset and frequency compensation interval (OFCI) and then separately optimize each interval. To demonstrate, the performance of this method, we implemented test benches using Ethernet-linked distributed control systems. We measured the peak-to-peak jitter performance along with the maximum time interval error to assess the short- and long-term stability after several hops in distributed control systems. Our method enables the peak-to-peak jitter to be maintained under 107 ns after seven hops. The experimental results show that the performance of time synchronization is dominated by fast jitter rather than frequency error and wander, and the proposed scheme can be used to improve the time synchronization performance in IEEE 1588-compliant control systems using boundary clock. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | A Novel Method for Providing Precise Time Synchronization in a Distributed Control System Using Boundary Clock | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jaehoon | - |
dc.identifier.doi | 10.1109/TIM.2009.2016365 | - |
dc.identifier.wosid | 000268033000054 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, v.58, no.8, pp.2824 - 2829 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT | - |
dc.citation.title | IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT | - |
dc.citation.volume | 58 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 2824 | - |
dc.citation.endPage | 2829 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordAuthor | Boundary clock | - |
dc.subject.keywordAuthor | IEEE 1588 | - |
dc.subject.keywordAuthor | network synchronization | - |
dc.subject.keywordAuthor | transparent clock | - |
dc.subject.keywordAuthor | unshielded twisted pair (UTP) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.