Optimal Pressure Regulation of the Pneumatic Ventricular Assist Device With Bellows-Type Driver
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Jung Joo | - |
dc.contributor.author | Kim, Bum Soo | - |
dc.contributor.author | Choi, Jaesoon | - |
dc.contributor.author | Choi, Hyuk | - |
dc.contributor.author | Ahn, Chi Bum | - |
dc.contributor.author | Nam, Kyoung Won | - |
dc.contributor.author | Jeong, Gi Seok | - |
dc.contributor.author | Lim, Choon Hak | - |
dc.contributor.author | Son, Ho Sung | - |
dc.contributor.author | Sun, Kyung | - |
dc.date.accessioned | 2021-09-08T15:08:52Z | - |
dc.date.available | 2021-09-08T15:08:52Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-08 | - |
dc.identifier.issn | 0160-564X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/119575 | - |
dc.description.abstract | The bellows-type pneumatic ventricular assist device (VAD) generates pneumatic pressure with compression of bellows instead of using an air compressor. This VAD driver has a small volume that is suitable for portable devices. However, improper pneumatic pressure setup can not only cause a lack of adequate flow generation, but also cause durability problems. In this study, a pneumatic pressure regulation system for optimal operation of the bellows-type VAD has been developed. The optimal pneumatic pressure conditions according to various afterload conditions aiming for optimal flow rates were investigated, and an afterload estimation algorithm was developed. The developed regulation system, which consists of a pressure sensor and a two-way solenoid valve, estimates the current afterload and regulates the pneumatic pressure to the optimal point for the current afterload condition. Experiments were performed in a mock circulation system. The afterload estimation algorithm showed sufficient performance with the standard deviation of error, 8.8 mm Hg. The flow rate could be stably regulated with a developed system under various afterload conditions. The shortcoming of a bellows-type VAD could be handled with this simple pressure regulation system. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | PORTABLE DRIVER | - |
dc.title | Optimal Pressure Regulation of the Pneumatic Ventricular Assist Device With Bellows-Type Driver | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Jung Joo | - |
dc.contributor.affiliatedAuthor | Choi, Jaesoon | - |
dc.contributor.affiliatedAuthor | Lim, Choon Hak | - |
dc.contributor.affiliatedAuthor | Son, Ho Sung | - |
dc.contributor.affiliatedAuthor | Sun, Kyung | - |
dc.identifier.doi | 10.1111/j.1525-1594.2009.00780.x | - |
dc.identifier.scopusid | 2-s2.0-68549122588 | - |
dc.identifier.wosid | 000268455500009 | - |
dc.identifier.bibliographicCitation | ARTIFICIAL ORGANS, v.33, no.8, pp.627 - 633 | - |
dc.relation.isPartOf | ARTIFICIAL ORGANS | - |
dc.citation.title | ARTIFICIAL ORGANS | - |
dc.citation.volume | 33 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 627 | - |
dc.citation.endPage | 633 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Transplantation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Transplantation | - |
dc.subject.keywordPlus | PORTABLE DRIVER | - |
dc.subject.keywordAuthor | Pneumatic VAD | - |
dc.subject.keywordAuthor | Bellows-type actuator | - |
dc.subject.keywordAuthor | Pressure regulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.