Development of a Closed Air Loop Electropneumatic Actuator for Driving a Pneumatic Blood Pump
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jeong, Gi Seok | - |
dc.contributor.author | Hwang, Chang Mo | - |
dc.contributor.author | Nam, Kyoung Won | - |
dc.contributor.author | Ahn, Chi Bum | - |
dc.contributor.author | Kim, Ho Chul | - |
dc.contributor.author | Lee, Jung Joo | - |
dc.contributor.author | Choi, Jaesoon | - |
dc.contributor.author | Son, Ho Sung | - |
dc.contributor.author | Fang, Yong Hu | - |
dc.contributor.author | Son, Kuk Hui | - |
dc.contributor.author | Lim, Choon Hak | - |
dc.contributor.author | Sun, Kyung | - |
dc.date.accessioned | 2021-09-08T15:12:35Z | - |
dc.date.available | 2021-09-08T15:12:35Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-08 | - |
dc.identifier.issn | 0160-564X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/119589 | - |
dc.description.abstract | In this study, we developed a small pneumatic actuator that can be used as an extracorporeal biventricular assist device. It incorporated a bellows-transforming mechanism to generate blood-pumping pressure. The cylindrical unit is 88 +/- 0.1 mm high, has a diameter of 150 +/- 0.1 mm, and weighs 2.4 +/- 0.01 kg. In vitro, maximal outflow at the highest pumping rate ( PR) exceeded 8 L/min when two 55 mL blood sacs were used under an afterload pressure of 100 mm Hg. At a pumping rate of 100 beats per minute (bpm), maximal hydraulic efficiency was 9.34% when the unit supported a single ventricle and 13.8% when it supported both ventricles. Moreover, pneumatic efficiencies of the actuator were 17.3% and 33.1% for LVAD and BVAD applications, respectively. The energy equivalent pressure was 62.78 similar to 208.10 mm Hg at a PR of 60 similar to 100 bpm, and the maximal value of dP/dt during systole was 1269 mm Hg/s at a PR of 60 bpm and 979 mm Hg/s at a PR of 100 bpm. When the unit was applied to 15 calves, it stably pumped 3 similar to 4 L/min of blood at 60 bpm, and no mechanical malfunction was experienced over 125 days of operation. We conclude that the presently developed pneumatic actuator can be utilized as an extracorporeal biventricular assist device. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | VENTRICULAR ASSIST DEVICE | - |
dc.subject | MECHANICAL CIRCULATORY SUPPORT | - |
dc.subject | CARDIAC SUPPORT | - |
dc.subject | PULSATILE | - |
dc.subject | PRESSURE | - |
dc.subject | SYSTEM | - |
dc.subject | PATIENT | - |
dc.subject | DRIVER | - |
dc.subject | DESIGN | - |
dc.title | Development of a Closed Air Loop Electropneumatic Actuator for Driving a Pneumatic Blood Pump | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jeong, Gi Seok | - |
dc.contributor.affiliatedAuthor | Hwang, Chang Mo | - |
dc.contributor.affiliatedAuthor | Nam, Kyoung Won | - |
dc.contributor.affiliatedAuthor | Ahn, Chi Bum | - |
dc.contributor.affiliatedAuthor | Lee, Jung Joo | - |
dc.contributor.affiliatedAuthor | Choi, Jaesoon | - |
dc.contributor.affiliatedAuthor | Son, Ho Sung | - |
dc.contributor.affiliatedAuthor | Son, Kuk Hui | - |
dc.contributor.affiliatedAuthor | Lim, Choon Hak | - |
dc.contributor.affiliatedAuthor | Sun, Kyung | - |
dc.identifier.doi | 10.1111/j.1525-1594.2009.00783.x | - |
dc.identifier.scopusid | 2-s2.0-68549125137 | - |
dc.identifier.wosid | 000268455500014 | - |
dc.identifier.bibliographicCitation | ARTIFICIAL ORGANS, v.33, no.8, pp.657 - U2 | - |
dc.relation.isPartOf | ARTIFICIAL ORGANS | - |
dc.citation.title | ARTIFICIAL ORGANS | - |
dc.citation.volume | 33 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 657 | - |
dc.citation.endPage | U2 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Transplantation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Transplantation | - |
dc.subject.keywordPlus | VENTRICULAR ASSIST DEVICE | - |
dc.subject.keywordPlus | MECHANICAL CIRCULATORY SUPPORT | - |
dc.subject.keywordPlus | CARDIAC SUPPORT | - |
dc.subject.keywordPlus | PULSATILE | - |
dc.subject.keywordPlus | PRESSURE | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | PATIENT | - |
dc.subject.keywordPlus | DRIVER | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordAuthor | Pneumatic actuator | - |
dc.subject.keywordAuthor | Portable biventricular assist device | - |
dc.subject.keywordAuthor | Extracorporeal | - |
dc.subject.keywordAuthor | Closed air-loop system | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.