Development of a Closed Air Loop Electropneumatic Actuator for Driving a Pneumatic Blood Pump

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Gi Seok-
dc.contributor.authorHwang, Chang Mo-
dc.contributor.authorNam, Kyoung Won-
dc.contributor.authorAhn, Chi Bum-
dc.contributor.authorKim, Ho Chul-
dc.contributor.authorLee, Jung Joo-
dc.contributor.authorChoi, Jaesoon-
dc.contributor.authorSon, Ho Sung-
dc.contributor.authorFang, Yong Hu-
dc.contributor.authorSon, Kuk Hui-
dc.contributor.authorLim, Choon Hak-
dc.contributor.authorSun, Kyung-
dc.date.accessioned2021-09-08T15:12:35Z-
dc.date.available2021-09-08T15:12:35Z-
dc.date.created2021-06-10-
dc.date.issued2009-08-
dc.identifier.issn0160-564X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/119589-
dc.description.abstractIn this study, we developed a small pneumatic actuator that can be used as an extracorporeal biventricular assist device. It incorporated a bellows-transforming mechanism to generate blood-pumping pressure. The cylindrical unit is 88 +/- 0.1 mm high, has a diameter of 150 +/- 0.1 mm, and weighs 2.4 +/- 0.01 kg. In vitro, maximal outflow at the highest pumping rate ( PR) exceeded 8 L/min when two 55 mL blood sacs were used under an afterload pressure of 100 mm Hg. At a pumping rate of 100 beats per minute (bpm), maximal hydraulic efficiency was 9.34% when the unit supported a single ventricle and 13.8% when it supported both ventricles. Moreover, pneumatic efficiencies of the actuator were 17.3% and 33.1% for LVAD and BVAD applications, respectively. The energy equivalent pressure was 62.78 similar to 208.10 mm Hg at a PR of 60 similar to 100 bpm, and the maximal value of dP/dt during systole was 1269 mm Hg/s at a PR of 60 bpm and 979 mm Hg/s at a PR of 100 bpm. When the unit was applied to 15 calves, it stably pumped 3 similar to 4 L/min of blood at 60 bpm, and no mechanical malfunction was experienced over 125 days of operation. We conclude that the presently developed pneumatic actuator can be utilized as an extracorporeal biventricular assist device.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectVENTRICULAR ASSIST DEVICE-
dc.subjectMECHANICAL CIRCULATORY SUPPORT-
dc.subjectCARDIAC SUPPORT-
dc.subjectPULSATILE-
dc.subjectPRESSURE-
dc.subjectSYSTEM-
dc.subjectPATIENT-
dc.subjectDRIVER-
dc.subjectDESIGN-
dc.titleDevelopment of a Closed Air Loop Electropneumatic Actuator for Driving a Pneumatic Blood Pump-
dc.typeArticle-
dc.contributor.affiliatedAuthorJeong, Gi Seok-
dc.contributor.affiliatedAuthorHwang, Chang Mo-
dc.contributor.affiliatedAuthorNam, Kyoung Won-
dc.contributor.affiliatedAuthorAhn, Chi Bum-
dc.contributor.affiliatedAuthorLee, Jung Joo-
dc.contributor.affiliatedAuthorChoi, Jaesoon-
dc.contributor.affiliatedAuthorSon, Ho Sung-
dc.contributor.affiliatedAuthorSon, Kuk Hui-
dc.contributor.affiliatedAuthorLim, Choon Hak-
dc.contributor.affiliatedAuthorSun, Kyung-
dc.identifier.doi10.1111/j.1525-1594.2009.00783.x-
dc.identifier.scopusid2-s2.0-68549125137-
dc.identifier.wosid000268455500014-
dc.identifier.bibliographicCitationARTIFICIAL ORGANS, v.33, no.8, pp.657 - U2-
dc.relation.isPartOfARTIFICIAL ORGANS-
dc.citation.titleARTIFICIAL ORGANS-
dc.citation.volume33-
dc.citation.number8-
dc.citation.startPage657-
dc.citation.endPageU2-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.subject.keywordPlusVENTRICULAR ASSIST DEVICE-
dc.subject.keywordPlusMECHANICAL CIRCULATORY SUPPORT-
dc.subject.keywordPlusCARDIAC SUPPORT-
dc.subject.keywordPlusPULSATILE-
dc.subject.keywordPlusPRESSURE-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusPATIENT-
dc.subject.keywordPlusDRIVER-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordAuthorPneumatic actuator-
dc.subject.keywordAuthorPortable biventricular assist device-
dc.subject.keywordAuthorExtracorporeal-
dc.subject.keywordAuthorClosed air-loop system-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Choon Hak photo

Lim, Choon Hak
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE