Micro-Cone Penetrometer for More Concise Subsurface Layer Detection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Woojin | - |
dc.contributor.author | Shin, Dong-Hyun | - |
dc.contributor.author | Yoon, Hyung-Koo | - |
dc.contributor.author | Lee, Jong-Sub | - |
dc.date.accessioned | 2021-09-08T15:47:58Z | - |
dc.date.available | 2021-09-08T15:47:58Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-07 | - |
dc.identifier.issn | 0149-6115 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/119745 | - |
dc.description.abstract | As the disturbance zone and measurement of soil properties are affected by the size of the penetrometer, a more local value may be measured by a smaller penetrometer. An ultra small Micro-Cone penetrometer with a 5 mm outer diameter is designed and manufactured to characterize soil properties with minimum disturbance during penetration tests. The tip resistance is measured by using strain gages attached near the Micro-Cone (MC) tip. A friction sleeve is adopted to effectively remove the skin friction from the tip resistance. Design concerns include the installation of strain gages, circuits, operating temperature, input voltage, penetration systems, penetration rate, sampling rate, and calibration. Application tests show that the air-clay interface, and the soil layers that consist of clay and sand are closely detected by the MC penetrometer. The cone tip resistances measured by the MC and the miniature cone with a 16 mm outer diameter are similar in clay. The strength change in sand after multiple liquefactions is clearly identified. This study shows that, with a relatively high resolution, the MC penetrometer may effectively detect the soil interface and yield the reasonable cone tip resistance. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER SOC TESTING MATERIALS | - |
dc.subject | PENETRATION TESTS | - |
dc.subject | SOILS | - |
dc.subject | RESISTANCE | - |
dc.subject | CLAY | - |
dc.title | Micro-Cone Penetrometer for More Concise Subsurface Layer Detection | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Woojin | - |
dc.contributor.affiliatedAuthor | Lee, Jong-Sub | - |
dc.identifier.scopusid | 2-s2.0-67651127516 | - |
dc.identifier.wosid | 000267876300007 | - |
dc.identifier.bibliographicCitation | GEOTECHNICAL TESTING JOURNAL, v.32, no.4, pp.358 - 364 | - |
dc.relation.isPartOf | GEOTECHNICAL TESTING JOURNAL | - |
dc.citation.title | GEOTECHNICAL TESTING JOURNAL | - |
dc.citation.volume | 32 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 358 | - |
dc.citation.endPage | 364 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Geology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Geological | - |
dc.relation.journalWebOfScienceCategory | Geosciences, Multidisciplinary | - |
dc.subject.keywordPlus | PENETRATION TESTS | - |
dc.subject.keywordPlus | SOILS | - |
dc.subject.keywordPlus | RESISTANCE | - |
dc.subject.keywordPlus | CLAY | - |
dc.subject.keywordAuthor | Micro-Cone penetrometer | - |
dc.subject.keywordAuthor | cone tip resistance | - |
dc.subject.keywordAuthor | layer detection | - |
dc.subject.keywordAuthor | liquefaction | - |
dc.subject.keywordAuthor | miniature cone | - |
dc.subject.keywordAuthor | calibration chamber | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.