Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty?
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Sang Won | - |
dc.contributor.author | Park, Jong Hoon | - |
dc.contributor.author | Han, Seung-Beom | - |
dc.contributor.author | Choi, Gi Won | - |
dc.contributor.author | Song, Dong Ik | - |
dc.contributor.author | An, Eun Soo | - |
dc.date.accessioned | 2021-09-08T18:26:09Z | - |
dc.date.available | 2021-09-08T18:26:09Z | - |
dc.date.created | 2021-06-10 | - |
dc.date.issued | 2009-04 | - |
dc.identifier.issn | 1011-8934 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/120323 | - |
dc.description.abstract | Despite advances in surgical techniques and instrumentation, current intra-operative estimations of acetabular version in total hip arthroplasty are of limited accuracy. In the present study, two experienced orthopedic surgeons compared intra-operatively measured (using portable imaging) anteversions and vertical inclinations of acetabular components with those measured using standardized radiographs post-operatively in 40 patients. Of the all vertical inclinations measured from intra-operative radiographs, 72.5% (n=29) were within +/-2 degrees, and 97.5% (n=39) were within +/-5 degrees of those determined using post-operative radiographs, and for anteversion, 52.5% (n=21) were within +/-2 degrees, and 97.5% (n=39) were within 5 degrees. Post-operative radiographs demonstrated that 90.0% (n=36) of vertical inclinations and anteversions were within the adequate zone. Obviously, our method has its limitations, but the authors conclude that the method described in this article better allows surgeons to verify acetabular version intra-operatively. In particular, the described method is suitable in cases with a deformed acetabular anatomy and difficult revision surgery. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN ACAD MEDICAL SCIENCES | - |
dc.subject | LOW-FRICTION ARTHROPLASTY | - |
dc.subject | DISLOCATION | - |
dc.subject | ACCURACY | - |
dc.title | Are Portable Imaging Intraoperative Radiographs Helpful for Assessing Adequate Acetabular Cup Positioning in Total Hip Arthroplasty? | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Park, Sang Won | - |
dc.contributor.affiliatedAuthor | Park, Jong Hoon | - |
dc.contributor.affiliatedAuthor | Han, Seung-Beom | - |
dc.identifier.doi | 10.3346/jkms.2009.24.2.315 | - |
dc.identifier.scopusid | 2-s2.0-67650376168 | - |
dc.identifier.wosid | 000265653600021 | - |
dc.identifier.bibliographicCitation | JOURNAL OF KOREAN MEDICAL SCIENCE, v.24, no.2, pp.315 - 319 | - |
dc.relation.isPartOf | JOURNAL OF KOREAN MEDICAL SCIENCE | - |
dc.citation.title | JOURNAL OF KOREAN MEDICAL SCIENCE | - |
dc.citation.volume | 24 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 315 | - |
dc.citation.endPage | 319 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART001336309 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | General & Internal Medicine | - |
dc.relation.journalWebOfScienceCategory | Medicine, General & Internal | - |
dc.subject.keywordPlus | LOW-FRICTION ARTHROPLASTY | - |
dc.subject.keywordPlus | DISLOCATION | - |
dc.subject.keywordPlus | ACCURACY | - |
dc.subject.keywordAuthor | Arthroplasty, Replacement, Hip | - |
dc.subject.keywordAuthor | Acetabular Cup | - |
dc.subject.keywordAuthor | Vertical Inclination | - |
dc.subject.keywordAuthor | Anteversion | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.