dc.description.abstractPortable gamma-ray imaging devices capable of responding to a broad energy range while providing reasonable angular resolution and efficiency are useful in a number of applications, including environmental remediation and industrial surveys. Due to this, a dual radiation imaging system that combines the advantages of a multi-aperture mechanical collimator with electronic-collimation has been designed, built, and tested. The combination of these two disparate imaging modalities offers both efficiency and good angular resolution, and is unique since a single gamma ray can contribute information to both modalities simultaneously. The Dual Modality Gamma Camera (DMGC) combines a high-resolution uniformly redundant array (URA) coded aperture with a Compton scatter camera to provide a broader range of energy response suitable for a wider range of industrial applications. The LaCl3(Ce) in the first detector module has 22 x 22 voxels, each voxel having a dimension of 2 x 2 x 5 mm(3). The LaCl3(Ce) in the second detector module has 6 x 6 voxels having dimensions of 4 x 4 x 10 mm(3). Both scintillators are coupled to position-sensitive photomultiplier tubes (PSPMT). The front-end, peak detection and coincident circuits of the DMGC are custom-designed for simplicity and compactness. Point and simulated ring radiation sources at intermediate energies (356 and 662 keV) are measured for mechanical, electronic and dual collimation and the reconstructed images are compared. The results show that the combined dual collimation image, using the maximum likelihood method for image reconstruction, yields better images than either a mechanical or an electronic collimation image at intermediate energies.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectEMISSION COMPUTED-TOMOGRAPHY-
dc.subjectEM RECONSTRUCTION-
dc.subjectCOLLIMATION-
dc.subjectLIKELIHOOD-
dc.subjectALGORITHM-
dc.subjectARRAYS-
dc.subjectSYSTEM-
dc.titleA Dual Modality Gamma Camera Using LaCl3(Ce) Scintillator-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Wonho-
dc.identifier.doi10.1109/TNS.2008.2011051-
dc.identifier.scopusid2-s2.0-60449115344-
dc.identifier.wosid000263767900015-
dc.identifier.bibliographicCitationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.56, no.1, pp.308 - 315-
dc.relation.isPartOfIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.titleIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.citation.volume56-
dc.citation.number1-
dc.citation.startPage308-
dc.citation.endPage315-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusEMISSION COMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusEM RECONSTRUCTION-
dc.subject.keywordPlusCOLLIMATION-
dc.subject.keywordPlusLIKELIHOOD-
dc.subject.keywordPlusALGORITHM-
dc.subject.keywordPlusARRAYS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordAuthorCompton camera-
dc.subject.keywordAuthordual camera-
dc.subject.keywordAuthorhybrid camera-
dc.subject.keywordAuthorLaCl3 (Ce)-
dc.subject.keywordAuthorscintillator-
dc.subject.keywordAuthoruniformly redundant array (URA)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE