Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography

Full metadata record
DC Field Value Language
dc.contributor.authorCho, Il-Hoon-
dc.contributor.authorPaek, Eui-Hwan-
dc.contributor.authorKim, Young-Kee-
dc.contributor.authorKim, Joo-Ho-
dc.contributor.authorPaek, Se-Hwan-
dc.date.accessioned2021-09-08T20:30:48Z-
dc.date.available2021-09-08T20:30:48Z-
dc.date.created2021-06-19-
dc.date.issued2009-01-26-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/120731-
dc.description.abstractA chemiluminometric biosensor system for point-of-care testing has been developed using an immunochromatographic assay combined with an enzyme (e.g., horseradish peroxidase) tracer that produces a light signal measurable on a simple detector. Cross-flow chromatography, a method previously investigated by our laboratory, was utilized in order to accomplish sequential antigen-antibody binding and signal generation. This enzyme-linked immunosorbent assay (ELISA) was effectively carried out on a plastic chip that was redesigned to simplify the fabrication process. To enhance the sensitivity, biotin-streptavidin capture technology was employed in preparing an immuno-strip that was then incorporated onto the chip in order to generate the ELISA-on-a-chip (EOC) biosensor. Samples containing cardiac troponin I (cTnI) were analyzed using the EOC. A chemiluminescent signal proportional to the analyte concentration was produced by adding a luminogenic substrate to the tracer enzyme complexed with the analyte on the chip. The luminescent signal was detected in a dark chamber mounted with a cooled charge-coupled device and the signal was converted to optical density for quantification. This EOC biosensor system was capable of detecting cTnI present in serum at concentrations as low as 0.027 ng mL(-1), 30 times lower than those measured using the conventional rapid test kit with colloidal gold as the tracer. In addition, the final data was acquired within 30s after the addition of the enzyme substrate. which was faster than the detection time required when using a colorimetric substrate with the same tracer enzyme. (C) 2008 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectCHEMILUMINESCENT IMMUNOSENSOR-
dc.subjectIMMUNOCHROMATOGRAPHIC ASSAY-
dc.subjectSYSTEM-
dc.subjectIMMOBILIZATION-
dc.subjectMEMBRANE-
dc.subjectBIOTIN-
dc.subjectSTRIP-
dc.subjectELISA-
dc.subjectCHIP-
dc.titleChemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography-
dc.typeArticle-
dc.contributor.affiliatedAuthorPaek, Se-Hwan-
dc.identifier.doi10.1016/j.aca.2008.11.019-
dc.identifier.scopusid2-s2.0-57849123141-
dc.identifier.wosid000262683800012-
dc.identifier.bibliographicCitationANALYTICA CHIMICA ACTA, v.632, no.2, pp.247 - 255-
dc.relation.isPartOfANALYTICA CHIMICA ACTA-
dc.citation.titleANALYTICA CHIMICA ACTA-
dc.citation.volume632-
dc.citation.number2-
dc.citation.startPage247-
dc.citation.endPage255-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusCHEMILUMINESCENT IMMUNOSENSOR-
dc.subject.keywordPlusIMMUNOCHROMATOGRAPHIC ASSAY-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusIMMOBILIZATION-
dc.subject.keywordPlusMEMBRANE-
dc.subject.keywordPlusBIOTIN-
dc.subject.keywordPlusSTRIP-
dc.subject.keywordPlusELISA-
dc.subject.keywordPlusCHIP-
dc.subject.keywordAuthorChemiluminometric signal-
dc.subject.keywordAuthorEnzyme-linked immunosorbent immunoassay (ELISA)-on-a-chip-
dc.subject.keywordAuthorBiotin-streptavidin capture-
dc.subject.keywordAuthorCardiac troponin I-
dc.subject.keywordAuthorCooled charge-coupled device-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science and Technology > Department of Biotechnology and Bioinformatics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE