Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Cho, Il-Hoon | - |
dc.contributor.author | Paek, Eui-Hwan | - |
dc.contributor.author | Kim, Young-Kee | - |
dc.contributor.author | Kim, Joo-Ho | - |
dc.contributor.author | Paek, Se-Hwan | - |
dc.date.accessioned | 2021-09-08T20:30:48Z | - |
dc.date.available | 2021-09-08T20:30:48Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2009-01-26 | - |
dc.identifier.issn | 0003-2670 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/120731 | - |
dc.description.abstract | A chemiluminometric biosensor system for point-of-care testing has been developed using an immunochromatographic assay combined with an enzyme (e.g., horseradish peroxidase) tracer that produces a light signal measurable on a simple detector. Cross-flow chromatography, a method previously investigated by our laboratory, was utilized in order to accomplish sequential antigen-antibody binding and signal generation. This enzyme-linked immunosorbent assay (ELISA) was effectively carried out on a plastic chip that was redesigned to simplify the fabrication process. To enhance the sensitivity, biotin-streptavidin capture technology was employed in preparing an immuno-strip that was then incorporated onto the chip in order to generate the ELISA-on-a-chip (EOC) biosensor. Samples containing cardiac troponin I (cTnI) were analyzed using the EOC. A chemiluminescent signal proportional to the analyte concentration was produced by adding a luminogenic substrate to the tracer enzyme complexed with the analyte on the chip. The luminescent signal was detected in a dark chamber mounted with a cooled charge-coupled device and the signal was converted to optical density for quantification. This EOC biosensor system was capable of detecting cTnI present in serum at concentrations as low as 0.027 ng mL(-1), 30 times lower than those measured using the conventional rapid test kit with colloidal gold as the tracer. In addition, the final data was acquired within 30s after the addition of the enzyme substrate. which was faster than the detection time required when using a colorimetric substrate with the same tracer enzyme. (C) 2008 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | CHEMILUMINESCENT IMMUNOSENSOR | - |
dc.subject | IMMUNOCHROMATOGRAPHIC ASSAY | - |
dc.subject | SYSTEM | - |
dc.subject | IMMOBILIZATION | - |
dc.subject | MEMBRANE | - |
dc.subject | BIOTIN | - |
dc.subject | STRIP | - |
dc.subject | ELISA | - |
dc.subject | CHIP | - |
dc.title | Chemiluminometric enzyme-linked immunosorbent assays (ELISA)-on-a-chip biosensor based on cross-flow chromatography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Paek, Se-Hwan | - |
dc.identifier.doi | 10.1016/j.aca.2008.11.019 | - |
dc.identifier.scopusid | 2-s2.0-57849123141 | - |
dc.identifier.wosid | 000262683800012 | - |
dc.identifier.bibliographicCitation | ANALYTICA CHIMICA ACTA, v.632, no.2, pp.247 - 255 | - |
dc.relation.isPartOf | ANALYTICA CHIMICA ACTA | - |
dc.citation.title | ANALYTICA CHIMICA ACTA | - |
dc.citation.volume | 632 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 247 | - |
dc.citation.endPage | 255 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | CHEMILUMINESCENT IMMUNOSENSOR | - |
dc.subject.keywordPlus | IMMUNOCHROMATOGRAPHIC ASSAY | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | IMMOBILIZATION | - |
dc.subject.keywordPlus | MEMBRANE | - |
dc.subject.keywordPlus | BIOTIN | - |
dc.subject.keywordPlus | STRIP | - |
dc.subject.keywordPlus | ELISA | - |
dc.subject.keywordPlus | CHIP | - |
dc.subject.keywordAuthor | Chemiluminometric signal | - |
dc.subject.keywordAuthor | Enzyme-linked immunosorbent immunoassay (ELISA)-on-a-chip | - |
dc.subject.keywordAuthor | Biotin-streptavidin capture | - |
dc.subject.keywordAuthor | Cardiac troponin I | - |
dc.subject.keywordAuthor | Cooled charge-coupled device | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.