An Implementation of Sensor-Based Force Feedback in a Compact Laparoscopic Surgery Robot
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Duk-Hee | - |
dc.contributor.author | Choi, Jaesoon | - |
dc.contributor.author | Park, Jun-Woo | - |
dc.contributor.author | Bach, Du-Jin | - |
dc.contributor.author | Song, Seung-Jun | - |
dc.contributor.author | Kim, Yoon-Ho | - |
dc.contributor.author | Jo, Yungho | - |
dc.contributor.author | Sun, Kyung | - |
dc.date.accessioned | 2021-09-08T20:57:44Z | - |
dc.date.available | 2021-09-08T20:57:44Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2009-01 | - |
dc.identifier.issn | 1058-2916 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/120781 | - |
dc.description.abstract | Despite the rapid progress in the clinical application of laparoscopic surgery robots, many shortcomings have not yet been fully overcome, one of which is the lack of reliable haptic feedback. This study implemented a force-feedback structure in our compact laparoscopic surgery robot. The surgery robot is a master-slave configuration robot with 5 DOF (degree of freedom corresponding laparoscopic surgical motion. The force-feedback implementation was made in the robot with torque sensors and controllers installed in the pitch joint of the master and slave robots. A simple dynamic model of action-reaction force in the slave robot was used, through which the reflective force was estimated and fed back to the master robot. The results showed the system model could be identified with significant fidelity and the force feedback at the master robot was feasible. However, the qualitative human assessment of the fed-back force showed only limited level of object discrimination ability. Further developments are underway with this result as a framework. ASAIO journal 2009; 55:83-85. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | LIPPINCOTT WILLIAMS & WILKINS | - |
dc.subject | SYSTEM | - |
dc.title | An Implementation of Sensor-Based Force Feedback in a Compact Laparoscopic Surgery Robot | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, Jaesoon | - |
dc.contributor.affiliatedAuthor | Sun, Kyung | - |
dc.identifier.doi | 10.1097/MAT.0b013e31819018e7 | - |
dc.identifier.scopusid | 2-s2.0-62449334750 | - |
dc.identifier.wosid | 000262425400017 | - |
dc.identifier.bibliographicCitation | ASAIO JOURNAL, v.55, no.1, pp.83 - 85 | - |
dc.relation.isPartOf | ASAIO JOURNAL | - |
dc.citation.title | ASAIO JOURNAL | - |
dc.citation.volume | 55 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 83 | - |
dc.citation.endPage | 85 | - |
dc.type.rims | ART | - |
dc.type.docType | Article; Proceedings Paper | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Transplantation | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Transplantation | - |
dc.subject.keywordPlus | SYSTEM | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.