해수중의 물질 분리 및 분석을 위한 Fl-FFF의 안정화 기법
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최수훈 | - |
dc.contributor.author | 이상엽 | - |
dc.contributor.author | 홍승관 | - |
dc.contributor.author | 문지희 | - |
dc.date.accessioned | 2021-09-08T21:55:07Z | - |
dc.date.available | 2021-09-08T21:55:07Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 2289-0971 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/121066 | - |
dc.description.abstract | Flow field-flow fractionation (Fl-FFF) device has been widely used to verify the size and molecular weight of various colloids and organics. The Fl-FFF, however, generally uses carrier solutions with only low to moderate ionic strengths to exclude the high affinity of materials to the membrane under high ionic strength conditions. Thus, materials existing in seawaters have not been accurately analysed based on the hydrodynamic size and molecular weight using current Fl-FFF techniques. The highest ionic strength tested was up to 0.1 M, while seawater ionic strength is about 0.6 M. The aim of this study is to accurately measure the hydrodynamic size of particles under carrier solutions close to seawater conditions with the Fl-FFF. By employing various operating conditions during the Fl-FFF analyses, it was demonstrated that the flow conditions, the concentration of surfactants, and stabilization times were key factors in acquiring compatible data. Results have shown that the cross flow was more influential factor than the channel flow. The concentration of the surfactant was to be at least 0.05% and the minimum 15 hr of stabilization was needed for accurate and reproducible data acquisition under seawater condition. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 한국물환경학회 | - |
dc.title | 해수중의 물질 분리 및 분석을 위한 Fl-FFF의 안정화 기법 | - |
dc.title.alternative | Stabilization Methods to Separate and Analyze Materials in Seawaters using Fl-FFF | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 홍승관 | - |
dc.identifier.bibliographicCitation | 한국물환경학회지, v.25, no.2, pp.288 - 294 | - |
dc.relation.isPartOf | 한국물환경학회지 | - |
dc.citation.title | 한국물환경학회지 | - |
dc.citation.volume | 25 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 288 | - |
dc.citation.endPage | 294 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001332933 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Flow field-flow fractionation (Fl-FFF) | - |
dc.subject.keywordAuthor | Fl-FFF stabilization | - |
dc.subject.keywordAuthor | Seawater | - |
dc.subject.keywordAuthor | Separation | - |
dc.subject.keywordAuthor | Flow field-flow fractionation (Fl-FFF) | - |
dc.subject.keywordAuthor | Fl-FFF stabilization | - |
dc.subject.keywordAuthor | Seawater | - |
dc.subject.keywordAuthor | Separation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.