dc.description.abstract | The purpose of this study is the comparison and analysis of Natural Ventilation Evaluation Method of an apartment house by using CFD. This study analyzes the method of CFD's modeling and compares the result with another. The comparison of this study is based on Ventilation Rate which is the methods of Boundary Condition between Velocity and Pressure. The Boundary Condition of this analysis is results between Velocity and Pressure by operating draft evaluation in a housing development. This study simulates the model of natural ventilation system which calculates the Loss Coefficient from ventilating amount of natural ventilation system in actual survey and verifies availability of Loss Coefficient which compares with actual ventilating amount. There is a noticeable distinction as a result of simulation between two models; the model which has a Boundary Condition of Pressure shows 127.8m³/h average ventilating amount and another model which has a Boundary Condition of Velocity shows 47.02m³/h average ventilating amount. For examining the validity of simulation, we make simulation of the Air Network. By showing 114.96m³/h average ventilating amount from the simulation of Air Network, it has 11.8% average error which has a similar result from model of Boundary Condition of Pressure and their variation of statistical graph was alike. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한건축학회 | - |
dc.title | CFD를 이용한 공동주택의 자연환기량 평가방법에 관한 연구 | - |
dc.title.alternative | A Study about Natural Ventilation Analysis Methods for Apartment Buildings Using CFD | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김강수 | - |
dc.identifier.bibliographicCitation | 대한건축학회논문집, v.25, no.06, pp.221 - 228 | - |
dc.relation.isPartOf | 대한건축학회논문집 | - |
dc.citation.title | 대한건축학회논문집 | - |
dc.citation.volume | 25 | - |
dc.citation.number | 06 | - |
dc.citation.startPage | 221 | - |
dc.citation.endPage | 228 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001357342 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | 자연환기 | - |
dc.subject.keywordAuthor | 자연환기창 | - |
dc.subject.keywordAuthor | 환기횟수 | - |
dc.subject.keywordAuthor | 전산유체역학 | - |
dc.subject.keywordAuthor | 기류네트워크 시뮬레이션 | - |
dc.subject.keywordAuthor | Natural Ventilation | - |
dc.subject.keywordAuthor | Natural Ventilated Window | - |
dc.subject.keywordAuthor | Ventilation Rate | - |
dc.subject.keywordAuthor | Computational Fluid Dynamics | - |
dc.subject.keywordAuthor | Network Airflow Simulation | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.